6
OPERATION
1
Switch on the machine with the power switch (lights up). The fog machine will heat
up for approx. 100 seconds. While the unit is warming up, fog output will not be
possible yet.
2
Once the warm-up process is completed, the green control indicator on the remote
control will light up. To activate the fog output, press the green button on the remote
control. While this switch is kept pressed, the unit will emit the maximum amount of
fog. As soon as you release the button, the fog output will stop.
3
After operation, switch off the machine with the power switch.
The output nozzle will heat up during operation. Therefore do not touch the nozzle until it has
cooled down completely!
Prior to transportation, allow the machine to cool down and completely empty the tank.
Never operate the fog machine without fog fluid. Fire hazard due to overheating! Besides, the
unit may be damaged.
During operation smoke emission may stop. In this case the device is heating up again. After a
short period, the machine will be ready to emit fog again. This process guarantees an
appropriate vaporization temperature and the best fog emission possible. The temperature is
regulated by a high-quality thermostat.
Notes
1
All fog machines develop condensation around the output nozzle. Because this may result in some
moisture accumulation on the surface below the output nozzle, consider this condensation when
installing your unit.
2
All fog machines may sputter small amounts of fog occasionally during operation and for a minute or so
after being turned off.
3
All fog machines have a recycling period after long bursts when the machine will shut itself down for a
short period in order to heat up again. During this time no fog can be produced.
4
If you experience low output, pump noise or no output at all, disconnect from mains immediately. Check
the fluid level, the external fuse, remote control connection and the power supply. If all of the above
appears to be ok, reconnect the unit again. If fog does not come out after holding the remote control
button on the remote control for 30 seconds, check the tube attached to the tank to make sure there is
fluid going through it. If you are unable to determine the cause of the problem, do not simply continue
pushing the remote button, as this may damage the unit. Return the machine to your dealer.