Herunterladen Inhalt Inhalt Diese Seite drucken

Dell PowerEdge C6100 Erste Schritte Mit Dem System Seite 17

Vorschau ausblenden Andere Handbücher für PowerEdge C6100:
Inhaltsverzeichnis

Werbung

Verfügbare Sprachen
  • DE

Verfügbare Sprachen

  • DEUTSCH, seite 52
Environmental (continued)
Altitude
Operating
Storage
Airborne Contaminant Level
Class
Operating
Storage
Altitude
Operating
Storage
Airborne Contaminant Level
Class
–16 to 3,048 m (–50 to 10,000 ft)
NOTE:
For altitudes above 2950 feet,
the maximum operating temperature
is derated 1ºF/550 ft.
–16 to 10,600 m (–50 to 35,000 ft)
G2 or lower as defined by ISA-S71.04-1985
One shock pulse in the positive z axis
(one pulse on each side of the system) of
31 G for 2.6 ms in the operational orientation
Six consecutively executed shock pulses in
the positive and negative x, y, and z axes
(one pulse on each side of the system) of
71 G for up to 2 ms
Six consecutively executed shock pulses
in the positive and negative x, y, and z axes
(one pulse on each side of the system) of
27 G faired square wave pulse with
velocity change at 235 inches/second
(597 centimeters/second)
–16 to 3,048 m (–50 to 10,000 ft)
NOTE:
For altitudes above 2950 feet,
the maximum operating temperature
is derated 1ºF/550 ft.
–16 to 10,600 m (–50 to 35,000 ft)
G2 or lower as defined by ISA-S71.04-1985
Getting Started With Your System
15

Werbung

Inhaltsverzeichnis
loading

Inhaltsverzeichnis