• Machine category according to the Directive 97/23EC (PED).
• The label position is shown in the drawing below.
Serial number identification:
• 1
st
nd
and 2
numbers = year of production
• 3
rd
and 4
th
numbers = week number of the year in which the machine was produced
• 5
th
, 6
th
, 7
th
and 8
4.

MACHINE DESCRIPTION

MX-SX units are condensing units and split system with housing for commercial refrigeration. They have
been designed to be installed outside. They are equipped with an electrical panel and a self-supporting
casing in epoxy-painted electrically galvanised steel.
5.

INSTALLATION

a) Before installing, it is necessary to make a layout of the refrigerating system; this must include the
following: all components of the refrigerating system ( i.e.: condensing unit, evaporator, thermostatic
valve, coldroom front electrical panel, piping dimensions, any safety devices, etc.)
b) system location
c) piping location.
• Installation must only be performed by qualified staff with the necessary technical requirements
according to the country in which the machine is installed.
• The machine must not be installed in a closed environment where good air flow is not guaranteed.
• Leave enough space around the condensing unit for it to be possible to perform maintenance
operations in safe conditions.
• Lift the machine by means of a forklift truck (or other hoisting equipment), inserting the forks into the
two tracks on the unit, as shown in Drawing 3. When installation is complete, remove the tracks by
unscrewing the relevant fastening screws.
• For information about weight, see the table of general features at the end of this manual.
• The machine must be placed on the floor in a vertical position only. It can be fixed to the floor by
passing screw anchors (Fischer) through the relevant holes in the unit frame.
5. 1
Evaporator installation
See Drawing 2 and attached documentation.
Drawing 1
th
numbers = progressive number
MX SX Pag. 13
REV. 14 11/05
UK