Herunterladen Inhalt Inhalt Diese Seite drucken

Bosch Professional RC Originalbetriebsanleitung Seite 375

Inhaltsverzeichnis
Assembly
Remote Control Power Supply
Using alkali-manganese batteries is recommended to oper-
ate the remote control.
To open the battery compartment cover (29), push the lock-
ing mechanism (28) in the direction of the arrow and re-
move the battery compartment cover. Insert the battery.
When inserting the batteries, ensure that the polarity is cor-
rect according to the illustration on the inside of the battery
compartment.
Remove the battery from the remote control when not
u
using it for longer periods. The battery can corrode and
self-discharge in the remote control during prolonged
storage.
Measuring Tool Power Supply
Inserting/changing the batteries
It is recommended that you use alkaline manganese batter-
ies to operate the measuring tool.
To remove the battery compartment (13), turn the locking
mechanism (14) to position 
. Pull the battery compart-
ment out of the measuring tool and insert the batteries.
When inserting the batteries, ensure that the polarity is cor-
rect according to the illustration on the inside of the battery
compartment.
Always replace all the batteries at the same time. Only use
batteries from the same manufacturer and which have the
same capacity.
Slide the battery compartment (13) into the measuring tool
and turn the locking mechanism (14) to position .
Take the batteries out of the measuring tool when you
u
are not using it for a prolonged period of time. The bat-
teries can corrode and self-discharge during prolonged
storage in the measuring tool.
Charge-control indicator
When the battery warning (12) flashes red for the first time,
the measuring tool can still be operated for approx. 2 hours.
When the battery warning (12) lights up red continuously,
no further measurements can be taken. The measuring tool
switches off automatically after 1 minute.
Operation
Protect the measuring tool and remote control against
u
moisture and direct sunlight.
Do not expose the measuring tool or remote control to
u
any extreme temperatures or variations in temperat-
ure. For example, do not leave them in a car for extended
periods of time. In case of large variations in temperature,
allow the measuring tool and the remote control to adjust
to the ambient temperature before putting them into op-
eration. Before continuing work with the measuring tool,
always perform an accuracy check (see "Accuracy Check
of the Measuring Tool", page 23).
Bosch Power Tools
The precision of the measuring tool may be compromised
if exposed to extreme temperatures or fluctuations in
temperature.
Avoid substantial knocks to the measuring tool and
u
avoid dropping it. Always carry out an accuracy check
before continuing work if the measuring tool has been
subjected to severe external influences (see "Accuracy
Check of the Measuring Tool", page 23).
Starting Operation of the Remote Control
When pressing the operating controls, it is possible to bring
the measuring tool out of its level position, so that the rota-
tion is briefly interrupted. This effect is avoided when using
the remote control.
The remote control remains ready for operation as long as a
battery with sufficient voltage is inserted.
Set up the measuring tool in such a manner that the signals
of the remote control can directly reach one of the
sensors (7). If the remote control cannot be pointed directly
at a sensor, the working range will be reduced. By reflecting
the signal (e.g. against walls), the working range can be im-
proved even for indirect signals.
After pressing a button on the remote control, the signal
transmission indicator (25) will light up, indicating that a sig-
nal has been sent out.
It is not possible to switch the measuring tool on/off with the
remote control.
Starting Operation of the rotary laser
Keep the work area free from obstacles that could re-
u
flect or obstruct the laser beam. For example, cover
any reflective or shiny surfaces. Do not measure
through panes of glass or similar materials. The meas-
urements may be distorted by a reflected or obstructed
laser beam.
Setting up the measuring tool
Horizontal position
Position the measuring tool on a stable surface in the hori-
zontal or vertical position, mount it on the tripod (32) or on
the wall mount (36) with the alignment unit.
Due to its high levelling accuracy, the measuring tool is very
sensitive to knocks and vibrations and changes in position.
Take care, therefore, that the measuring tool is stable to
avoid interruptions to the operation caused by relevelling.
Switching On and Off
To switch on the measuring tool, press the on/off
button (4). All indicators light up briefly. The measuring tool
emits the variable laser beam (6) and the upwards plumb
point (9) from the outlet apertures (8).
English | 21
Vertical position
1 609 92A 8LJ | (07.06.2023)
Inhaltsverzeichnis
loading