Step 2: Connect to Grid Power
• The grid connection must be connected to a grounded electrical outlet or grounding busbar. Additionally,
grounding the product casing via its dedicated grounding terminal is recommended for enhanced safety.
• Ensure the device is powered off before installation.
• Method 1: Connect via a Home Outlet
A3
×1
• Method 2: Connect via a Home Circuit Breaker (United Kingdom Only)
• Professional Installation Required: This step must be carried out by a qualified electrician.
• Power Must Be Off: Before beginning installation, ensure the power is switched off at the installation site.
• The PE and N wires should be connected separately to the PE-bar and Neutral-bar, and the L wire should be
connected to the terminal on the breaker that leads to the load side.
A3
×1
❶
Click
A3
❶
❷
Click
❷
PH0
PH0
A3
en