The stay-ON time s restarted by any movement before this time elapses. The
GB
shortest time setting is recommended when adjusting the detection zone and
performing the functional test.
Note: every time the light switches OFF, it takes approximately 6 seconds for
the sensor to start detecting movement again. Only after this time elapses can
the sensor switch turn light ON again in response to motion.
LED ON / OFF
If you are irritated by the status LED, it can easily be switched OFF.
Briefly (1 second) set control dial to LED ON / OFF.
LED flashes once: LED is ON.
LED flashes twice: LED is OFF.
The control dial must then be adjusted to the chosen time setting. If this is not
done, the time set is 2 minutes.
Switch for light function (Fig� 6�2/H)
Light ON status: press once
Light goes out. If no movement is being detected, the stay-ON time elapses and
the sensor switches to normal sensor mode.
Light OFF status: press once
Light come ON even in sufficient ambient brightness. The light stays switched
ON until the sensor switch turns it OFF because no movement is being detected
or ambient brightness is sufficient.
Teach mode
Teach mode saves the current ambient light level below which you do not want
the sensor to respond to movement from now on.
Pressing the button for 5 seconds programs in the light level. This takes place
5 seconds after releasing the button to prevent any shadow being cast over
the brightness sensor. The LED flashes once to indicate that Teach mode has
been selected. The connected lamp is switched OFF while the Teach cycle is in
progress. The LED flashes once to confirm that the current ambient light level
has been saved. The sensor switch then returns to sensor mode and operates
with the new threshold. Teach mode can be repeated any number of times.
To quit Teach mode, turn the twilight setting control dial.
- 25 -