5� Mounting
• Check all components for damage.
• Do not use the product if it is damaged.
• Select an appropriate mounting location, taking the reach and motion
detection into consideration.
Mounting procedure
• Switch OFF power supply (Fig� 4�1)
• Connect conductors to load module.
– 2-wire connection (Fig� 5�1a)
– 3-wire connection (Fig� 5�1b)
• Push load module into the flush-mounting box (Fig� 5�2)
• Screw load module into place (Fig� 5�3)
• Fit surround and sensor module on load module (Fig� 5�4)
• Switch ON power supply (Fig� 5�5)
• Settings
"6� Function"
6� Function
Factory settings:
Twilight setting: 1,000 lux (daylight mode)
Time setting: 5 seconds
To make settings, you must open the sensor module.
• Press a screwdriver onto the tab and open the flap (Fig� 6�1)
Twilight setting (Fig� 6�2/B)
The sensor's response threshold can be set in increments from 2 lux to
1,000 lux or in relation to ambient light level.
Control dial set to
Control dial set to
The control dial must be turned to
performing the functional test in daylight.
Time setting (Fig� 6�2/C)
The time you want the connected lamp to stay ON for can be set in increments
from 5 seconds to a maximum of 30 minutes.
Control dial set to 5 s:
Control dial set to 5 min: 5 minutes
Control dial set to 30 min: longest time (30 minutes)
: daylight operation (independent of ambient light level)
:
twilight operation (2 lux)
shortest time (5 seconds)
when adjusting the detection zone and
- 24 -