3.Be sure to ground the generator when the connected equipment is
grounded.
4.Start each engine according to ''STARTING THE ENGINE''.
• When the Output indicator (green) does not light and the Overload
indicator (red) lights instead, set the engine switch to STOP, stop
the engine once, and then start the engine again.
5.Confirm that the equipment to be used is switched off, and insert the
plug of the equipment to be used into the AC receptacle of the
receptacle box.
CAUTION:
Confirm that the use equipment to be connected is switched off.
When the equipment to be used is switched on, it will operate
suddenly, and injuries or accidents may be caused.
36
RECEPTACLE BOX
GROUND TERMINAL
AC RECEPTACLE