ALARMS
A1
A2
A3
A4
A5
K1
K2
k3
F2
File: v_C90_C81_ALL LANGUAGES – 23/02/2023 - Hoonved Ali Group s.r.l. a socio unico
FAST OPERATING MANUAL
A1 – Failure to complete che cycle
If the machine, during the cycle phase (washing, pause or rinsing), is switched OFF and the cycle is in
this way interrupted, the display will show the alarm A1.
To delete this alarm, it's necessary to switch OFF the main switch or to start a new cycle (it will be
counted from the beginning, not from the point in which the previous cycle has been interrupted).
N.B. the START button backlight does not change from the previous state..
A2 – Boiler overheating
The alarm indicates a water overheating that can be both in the boiler and in the tank.
The alarm is displayed if the temperature probes are in short-circuit or if the temperature of boiler
or/and tank is higher than 105°C.
The alarm will be deleted when the temperature goes under 102°C.
A3 – Boiler and/or tank temperature probe broken or disconnected
The alarm indicates the interruption of one or both temperature probes, due to their
disconnection, or that one of the probes is faulty.
The alarm will reset when the card reads the correct connection of the two probes. Check the
correct connection of the probes and that they are not interrupted.
A4 – Lack of water in the tank
This alarm appears if a situation of lack of water in the tank or failure to reach the level in the tank
within 30 minutes is detected.
To reset the alarm, the machine must be switched off and on again, thus restarting the filling phase.
A5 –
Boiler failing to heat
The display shows this alarm if the water in the boiler doesn't reach the selected temperature (t2)
within 30 minutes. All the electrical loads will be immediately deactivated.
To delete this alarm, it is necessary to switch OFF the machine.
H1 –
Insufficient temperature of rinsing water
During the rinsing phase, if the temperature of the boiler water is lower than 15°C or higher than
the selected temperature (t2), the display will visualize the alarm H1.
With rinse-check function activated, if the temperature of the boiler water doesn't reach the value
selected (t2), the washing phase will be extended for a maximum of 8 minutes.
To delete this alarm, it is necessary to switch OFF the machine, also through IL button, or to start a
new cycle with the right temperature value.
H2 –
Insufficient quantity of rinse water (only BT models)
This alarm occurs when the rinsing phase is not performed or when the rinsing phase is partially
performed.
To reset this alarm, switch off and restart the machine, and check that the level probes or the pressure
switch are working properly.
H3 –
Insufficient temperature of washing water
During the washing phase, if the temperature of the tank water is lower than 10°C or higher than the
selected temperature (t1), the display will visualize the alarm H3.
To delete this alarm, it is necessary to switch OFF the machine, also through IL button, or to start a
new cycle with the right temperature value.
F1 – Door open
When the door is open (during the cycle or with the machine in stand-by), the display shows this
message. If the door is closed while the alarm is displayed, this may indicate a problem with the
positioning of the door microswitch or that it is not working properly.
Note:. the START button backlight does not change from the previous state.
F2 – Filling
This message is displayed throughout the filling phase, until the tank reaches the level.
Wait until the filling phase is complete. If the alarm remains displayed, check the correct operation of
the pressure switch.