Operation
5
Operation
5.1
Status display
5.1.1 Switching on the status display
Switch the switch (Fig� 2-1) downwards to position
The green (Fig� 2-7) or red (Fig� 2-6) LED on the con-
trol panel is lit and shows the status of the operating
cylinder�
Green LED lit
The operating cylinder is full�
Gas is withdrawn from the operating cylinder�
Red LED lit
The operating cylinder is empty and the DuoControl CS
has switched over to the reserve cylinder�
Gas is withdrawn from the reserve cylinder�
5.1.2 Switching off the status display
Switch the switch (Fig� 2-1) to the middle to
position
All LEDs are off�
16
EN
5.2
EisEx
5.2.1 Switching on EisEx
Switch the switch (Fig� 2-1) upwards to position
The yellow LED (Fig� 2-5) on the control panel is lit�
The gas pressure regulator in the gas box is being heat-
ed by the heating cartridge (winter mode)�
The status display is also switched on�
The green (Fig� 2-7) or red (Fig� 2-6) LED on the con-
trol panel is lit and shows the status of the operating
cylinder�
5.2.2 Switching off EisEx
Set the switch (Fig� 2-1) to the middle to position
All LEDs are off�
The gas pressure regulator in the gas box is not heated�
6
Faults
Below are some measures to remedy faults� If these
measures do not work, contact Truma Service�
Although the remote indicator is switched on, the
LEDs on the control panel are not lit.
Check the 12 V power supply�
Check fuses and replace if necessary�