Verfügbare Sprachen

Important:
Please keep in mind that some delay or even malfunction in the exchange of alerts between
the Lisa-Signolux system and their indication on the app may be possible.
This can be caused by multiple factors, which are beyond the control of the Humantechnik
GmbH.
The Humantechnik GmbH and its partners can and will not accept any liability for possible
consequences of delayed or missed transmission of information.
Troubleshooting
Faults in Lisa-Signolux basic functions:
Symptom: The receiver does not work
- Check if the power supply unit is connected and receives power.
- The rechargeable batteries may be inserted incorrectly. Ensure the correct orientation of the
rechargeable batteries.
- The transmitters and receiver are out of transmission range. Try using the transmitter or
receiver at a different location.
Symptom: The transmission range is reduced
- Metal structures and other building materials can reduce the transmission range. If possible
do not mount the transmitter or receiver near or on metal parts.
- Interference from other devices. Avoid setting up Lisa-Signolux devices close to mobile
phones and display screens.
- Walls and ceilings reduce the range. Reduce the distance between the transmitters and the
receiver or try a different location for the devices.
Symptom: The red status LED lights up with an alert
This indicates a low battery in the according transmitter. Insert new batteries in the transmitter.
Symptom: There is no alert tone
- Check the position of the mode selector switch (10) on the rear of the receiver. See page 19.
- Ensure that the volume control (7) is not set to the lowest setting.
Symptom: The flash does not work
- Check the position of the mode selector switch (10) on the rear of the receiver. See page 19.
Symptom: When trying to pair a transmitter, a different icon lights up
The transmitter you are trying to pair has already been paired with the receiver. Delete the trans-
mitter from the unwanted icon before linking it to a new icon. See page 21.