TROUBLESHOOTING GUIDE (continued)
TROUBLE
FOG OR MOISTURE
• Condensation due to ambient
INSIDE THE FILTER
GAUGE WINDOW
FILTER CARTRIDGE
• Plunger valves are not open or fully
IS DIRTY, BUT THE
INDICATOR IS IN THE
• Filter cartridge not correctly installed
GREEN ZONE
• Incorrect filter cartridge specification.
• Filter cartridge is broken and leaking.
• Accessories attached to the water
• Hoses are twisted, kinked or tangled.
• The filter gauge is broken.
AFTER CLEANING
• Filter cartridge is not completely clean.
THE CARTRIDGE, THE
• Filter cartridge cannot be cleaned.
INDICATOR IS STILL IN
• The filter gauge is broken.
THE YELLOW ZONE
FILTER CARTRIDGE
• There may be algae clogged inside the
SEEMS CLEAN, BUT
THE INDICATOR IS IN
• The filter gauge is broken.
THE RED ZONE
TIMER IS INACCURATE
• Possible inner timer defective.
OR TIMER CAN'T BE
SET
SAVE THESE INSTRUCTIONS
(110) MODEL FP634 FILTER PUMP ENGLISH 7.5" X 10.3" PANTONE 295U 08/23/2024
CAUSE
temperature variation and high humidity
level.
open.
inside the filter housing.
filtration system line.
filter cartridge.
English
SOLUTION
• This is normal.
• Make sure all the plunger valves are fully
open.
• Make sure the cartridge is installed
correctly inside the filter housing and the
housing cover is securely closed.
• Replace with INTEX filter cartridge.
• Replace the filter cartridge with a new one.
• Remove any accessories (skimmer,
lights, water sprayer, auto cleaner, heater,
sanitation, vacuum device, etc) from the
filtration inlet and outlet line.
• Make sure all the hoses are fully extended.
• Replace a new filter gauge.
• Soak and clean the cartridge thoroughly
again. Use a brush to clean between the
pleats.
• Replace with a new filter cartridge.
• Replace a new filter gauge.
• Soak and clean the cartridge thoroughly. If
it's still in the red zone, replace with a new
filter cartridge.
• Replace a new filter gauge.
• Turn off the pump and restart 5 minutes
later.
• Re-set the timer.
• Contact Intex service center.