INSTALLATION AND POSITIONING

INSTALLATION and POSITIONING
Bring the dishwasher to the installation site, remove the packaging and check the appliance and components for damage; any
damage found must be reported to the transporter in writing. The packaging components (plastic bags, expanded polystyrene,
nails, etc.) must not be left within reach of children and pets since they are potentially dangerous. All packaging materials used
are environment-friendly. They can be kept without constituting any hazard, or may be disposed of at a specialist waste disposal
centre. The plastic components suitable for recycling are marked as follows: PE polyethylene: external packaging film, bag
containing the instructions, protective bags. PP polypropylene: straps. PS expanded polystyrene: corner guards, top of
packaging. Wooden and cardboard components can be disposed of in accordance with the relevant regulations.
When the product is decommissioned it must not be dumped in the environment; it must be disposed of in accordance with the
relevant regulations. All metal parts are in stainless steel and can be removed. The plastic parts are marked with the symbol
identifying the material used.
POSITIONING
Warning: the indoor system and premises in which equipment for institutions is installed must comply with
the relevant regulations.
The manufacturer declines all liability for direct or indirect injury or damage deriving from failure to comply with these
regulations. Before installation, check that there are no objects or materials in the vicinity which may be damaged by steam or
splashes of washing solution, or that any such items are suitably protected. Place the dishwasher in the chosen point and
remove the protective film. Level the dishwasher (with the aid of a spirit level) on its adjustable feet to ensure that it is stable;
all other mounting solutions must be approved by the manufacturer.
4

INSTRUCTIONS FOR TECHNICAL STAFF

4.1 Plumbing hookup

The water pipelines and electricity supply cable lead out of the bottom right-hand corner of the appliance.
Connect the water intake hose to a connector with ¾" gas threaded fitting, fitting the filter A provided (in
models with Acquastop, the filter and ring-nut form a single unit). The connection to the water mains must
only be made with new hoses; the use of old or worn hoses is not permitted.
The dynamic water supply pressure must be between 2 and 6 bar; if it is higher, installation of a pressure reducer is necessary.
If the pressure is less than 2.5 bar it might be necessary to fit a special pump on the appliance to ensure optimal performance.
Contact the After-Sales Service. It is essential to fit a main stop tap on the water intake deliver pipeline; the tap must be
accessible after installation of the appliance, so do not install it behind the dishwasher. The stated cycle duration applies to
appliances supplied with hot water >50°C<60°C. If the dishwasher is supplied with cold water, the cycle duration might increase
depending on the intake water temperature. Drainage: The dishwasher is fitted with a drain pump and can operate with drain
connections on the floor or wall. Refer to the connection diagram for the maximum permitted height of wall drains – (see