Safety
Connected plastic lines might be thermally stressed to an impermissible degree
and damaged.
If the heating cycle is not locked with the circulating/filter pump, the heat exchan-
take care
ger might heat up to the flow temperature of the heating water.
The heat exchanger might be damaged.
If dripping water falls onto the outer skin or if metal particles enter the heat exchan-
ger, the risk of contact corrosion exists.
take care
Bathwater might be contaminated.
If metal particles have entered the heating spiral of the heat exchanger, it might
develop leaks due to contact corrosion. Heating water might reach bathwater.
take care
1.5
Safety Measures on the Installation Site
The heat exchanger is to be installed in a frost-proof room with a mounting device
made of plastic or stainless steel.
Please ensure that the maximum operational overpressure of 3.0 bar on the secon-
dary side or 10 bar on the primary side is not exceeded.
The heat exchanger or the environment might be damaged.
Please check the heat exchanger and its connections for tightness and visible
damage once a week during operation.
take care