Table 2
Error
The engine does not
start.
The device starts, but
blocks at low load
and may switch off
automatically.
The motor does not
generate any power.
EN
V. 1.0
Troubleshooting
Possible cause
The mains voltage is
missing.
Connection cable
defective.
Motor or switch
connections not in order.
Motor or switch defective.
Extension cable too long
or cross-section too small.
The socket outlet is too
far away from the main
connection and the cross-
section of the connection
cable is too small.
Cross-section of the
extension cable not
sufficient.
Overload.
Solution
Check the cables.
Have them checked
or replaced. (qualified
electrician)
Have it checked by an
electrician.
Extension cable with at least
1.5 mm² and a maximum
length of 25 m.
Shorter cables with a cross-
section of at least 2.5 mm².
Extension cable with at least
1.5 mm² and a maximum
length of 25 m.
Check the device.
19