6. OPERATING
INSTRUCTIONS
ATTENTION: The temperature during operation must be between -IOOC and +500C
ANDERSON PLUGS USE (DC operation)
The DC12V Anderson plugs on LithPowerUnit provide a convenient option to connect DC12V appli-
ances and accessories such as DC fridge, DC TV, electric pumps, light kits etc.
The LithiumPowerUnit
1 * 175Amp Plug
(the 175 A Anderson plug can be connected to an external inverter, max. 1800 W).
3 * 50Amp plug (can be used as input and output plug)
15Amp solar input.
1*
The LithiumPowerUnit
1*
175Amp plug
(the 175 A Anderson plug can be connected to an external inverter, max. 1800 W).
2 * 50Amp plug (can be used as input and output plug)
1 * Anderson in-vehicle charging input 50Amp
I * 30Amp solar input.
NOTE: Before doing the charge or discharge, please turn on the Battery Main Switch firstly. The
charging current or discharging current of 50 Amp Anderson plug must be less than 50A, other-
wise, the circuit breaker will be triggered and cut off the power.
CAUTION! The circuit breaker of 50Amp Anderson plug resets automatically, please check the
connections and make sure the electrical fault in the circuit is fixed. The circuit breaker will be trig-
gered again, if an electrical fault still exists. Pleaseavoid short circuit of any Anderson plug!
A 40A inline fuse cable is provided for the MPPT solar charge controller which protects the device
USB Port & Cigarette Lighter Socket
There are 2 * 2.IAmp USB ports and 2 * cigarette lighter sockets (against customized require
ment) on LithPowerUnit to charge personal electronics.
NOTE: Before charging your personal electronics, please turn on the Battery Main Switch firstly.
The charging current must be less than IOA of each plug, otherwise, the circuit breaker will be trig
gered and cut off the power. If the internal 30A fuse is broken due over-current it must be
replaced.
CAUTION! Before replacing the circuit breaker, please check the connections and make sure the
electrical fault in the circuit is fixed. The circuit breaker will be triggered again, if an electrical fault
still exists.
80 is equipped with 5 * Anderson plugs:
120 is equipped with 5 * Anderson plugs:
CARBEST LithPowerUnit 80 & 120 | 814136
18