Setting parameters in the menu (Continuation)
Setting the output deactivation delay
The deactivation delay causes the output to be turned off
only some time after the reference marking leaves the
acquisition range.
This enables slower interfaces to capture shorter pulses as
well.
Object
acquired
not acquired
Output
Fig. 7: Function of the turn-off delay
Procedure
1. Open the "MEnu" menu (see key functions).
2. Select menu item "dlOF".
3. Press the SET key to activate programming.
The previously set value is displayed, e.g. "dl00".
4. Use the + and – keys to increase or decrease the
value. Value range: 0...100 ms in steps of 1 ms.
The DELAY-LED comes on as soon as a value not
equal to zero is set.
5. Save the value by pressing the SET key
Setting PNP or NPN
The digital output can be configured as PNP or NPN.
Factory default setting: PNP
Procedure
1. Open the "MEnu" menu (see key functions).
2. Select menu item "_PnP" or "_nPn" (depending on the
previous setting).
3. Use the SET key to change the previously set output
type.
Setting read direction on the display
Factory default setting: Display up.
Procedure
1. Open the "MEnu" menu (see key functions).
2. Select "dSUP" or "dSdn" (depending on the previous
setting).
3. Use the SET key to change the previously set display
direction.
11
Turning the display on and off
To reduce power consumption the display can be turned off
during normal operation. If a key is pressed however, the
display automatically turns on for 5 s.
Factory default setting: Display on.
Procedure
1. Open the "MEnu" menu (see key functions).
2. Select "dSOn" or "dSOF" (depending on the previous
setting).
3. Use the SET key to change the previously set function.
Saving values
Use either of these methods:
Menu item "SAVE"
Automatically if neither "SAVE" nor "rSEt" has been
activated within 30 s.
Procedure
1. Save values.
2. Select "SAVE".
3. Save the previously set values by pressing the SET key.
Operational and error indication
RDY LED
Function/error
Off
Data are being read
On
Settings correct, the sensor is
operational
Blinks rapidly
Short circuit, or output current
exceeded
Display
Function/error
FAIL
Static acquisition of marking or
background failed.
Lo
Dynamic acquisition of contrast
between marking and background
failed.
_SC_
Output overload.
Remedy: Remove overload.
Photoelectric Sensors
Contrast Sensor BKT 67M-005/006-U-S92
Detection diagrams
(standard lens)
Fig. 8: Relative sensitivity as a function of object distance
Accessory lenses
Order
Lenses
Focal
Light spot
code
length
BAM0120 BKT M-PK-1
18 mm
2 x 7 mm
BAM0121 BKT M-PK-2
9 mm
1.5 x 4 mm
(Standard lens
included in delivery)
BAM0122 BKT M-PK-3
28 mm
2 x 9 mm
BAM00P2 BKT M-PK-4
9 mm
1.5 x 5 mm
BAM00P3 BKT M-PK-5
40 mm
2.5 x 11 mm
www.balluff.com

Technical Data

Optical
Range with standard lens
9 mm
(included in delivery)
Depth of field with standard lens
±3 mm
Recommended range with standard
9 ±3 mm
lens
Light spot dimension with standard
< 1.5 x 5 mm
lens
(vertical)
Light type (autom. selected)
blue (465 nm)
green (520 nm)
red (630 nm)
Electrical
Supply voltage U
10...30 V DC
B
Ripple
< 2 V
No-load current I
< 35 mA
O
Effective operating current I
100 mA
e
Effective operating voltage V
24 V DC
e
Voltage drop V
at I
< 2 V
e
d
Output selectable
PNP/NPN,
N.O./N.C.
Short circuit protected
yes
Reverse polarity protected
yes
Light-on/dark-on
switching automatic
Mechanical
Connection type
M12-connector, 5-pin
Housing material
Al
Active surface material
Glas
Weight
170 g
Indicators
Output function indicator
yellow LED OUT
Power indicator
green LED RDY
green LED
Delay indicator
green LED
Keylock indicator
Switching threshold display
digital
Scattered light indicator
4-digit display
Time Data
Switching frequency f at V
30 kHz
e
Turn-on delay t
< 17 ms
on
Turn-off delay t
< 17 ms
off
Output delay selectable
0...10 ms
Power-on delay t
< 300 ms
v
Ambient
Ambient temperature T
–10... +55°C
a
Storage temperature
–20... +70°C
Enclosure rating per IEC 60529
IP 67
Ambient light rejection
per EN 60947-5-2