Replace drain plug.
Remove lid assembly.
Remove sleeve.
Clean
Dose with MC1+ Protector
O ring
The lid seal should be cleaned and checked for
wear when servicing MagnaClean. It is Best
Practice to replace the lid and drain valve seals
at each service.
"Only use Silicon grease or water to lubricate
O ring.
Do not use flux or EP grease."
Turn locking pin 90° and remove.
CAUTION: Ensure valves are off
Disconnect.
Remove.
CAUTION: Clean and inspect collets and
lubricate seals with water only.
Fit quick release trigger and canister onto
valves.
CAUTION: Ensure canister is firmly pushed onto
valves until fully engaged.
Replace locking pin and turn 90° to lock
Ablassschraube wieder anbringen.
Deckelbaugruppe entfernen.
Manschette entfernen.
Reinigen
MC1+ Protector dosieren
O-Ring
Bei der Wartung von MagnaClean sollte auch
die Deckeldichtung gereinigt und auf Verschleiß
überprüft werden. Es hat sich bewährt, bei jeder
Wartung die Deckel- und
Ablassventildichtungen auszutauschen.
"O-Ring nur mit Silikonschmierfett oder
Wasser schmieren.
Kein Flux- oder EP-Schmierfett verwenden."
Verriegelungsstift um 90° drehen und
entfernen.
VORSICHT: Die Ventile müssen auf Aus stehen.
Trennen.
Entfernen.
VORSICHT: Klemmhülsen reinigen und
untersuchen, Dichtungen nur mit Wasser
schmieren.
Schnellspanner und Behälter an den Ventilen
montieren.
VORSICHT: Behälter kräftig auf die Ventile
drücken, bis er fest sitzt.
Verriegelungsstift wieder anbringen und zum
Verriegeln um 90° drehen.