7.6

Leak detection

Fig. 20: Refrigerant detected
7.7

Lighting

7.8
After the leak de-
tection
8

Error codes

Error code
Error
E1
The fan is damaged.
E2
Sensor error
Guide the sensor slowly (approx. 2 cm/s)
along both sides of the cables.
As soon as the device approaches a leak, the bar
display shows the corresponding refrigerant con-
centration and the signal tone rate or vibration fre-
quency increases in proportion to the refrigerant
concentration.
In dark surroundings, the display lighting and the
two LED lamps switch on automatically.
To switch the lighting on manually, cover the
sensor below the switch-on button with your
thumb.
Ventilate the sensor thoroughly after each
use. To do this, expose the device to fresh air
for approx. 2 minutes before carrying out a
new leak detection.
Measure
Send the device in for repair.
If E2 is still displayed after switching on
again, change the sensor.
Error codes
EN