DISASSEMBLY / REASSEMBLY OF THE COUPLING (BELLOWS)
Guards (air motor cover, coupling shields, housings ...) have been designed for
The manufacturer will not be held responsible for bodily injury or failure and / or
damage to property due to removal or partial removal of the guards
Disassemble the fluid section prior to carrying out the following procedure :
BELLOWS
Unscrew nuts (14) from the tie-rods.
Remove suction flange (1) and cylinder (2) by pulling them downwards.
Remove screws (12) to disconnect suction bearing (3) from air motor.
Disconnect intermediate piston (9) from air motor rod.
Remove coupling parts.
Remove bellows flange (4) by unscrewing screws (13) to free the upper part of the bellows.
Unscrew skirt (8) to free the lower part of the bellows.
Replace bellows (5).
When installing bellows push it into skirt firmly (8).
Insert intermediate piston (9) into bellows (5) and screw the skirt at the piston end.
Insert bellows and piston (9) into the suction bearing (3).
Install flange (4) in the suction bearing and tighten the whole with screw (13).
Connect bellows-piston set to motor rod and secure the whole on the lower support of the air motor
by using screws (12).
Reinstall fluid section piston (24) on intermediate piston (9).
Replace seals (11). Then install cylinder (2) and suction flange (1).
Install the whole on tie-rods and tighten it with nuts (14).