2. Installing the COalarm in a bedroom or room without a fuel-burning appliance (see Figure 2):
• Mount the CO alarm relatively close to the breathing zone ofthe occupant.
• Install the alarm such that the LEDindicator is viewable when the occupant is near the alarm.
Figure 2: Installation in a bedroom or room without a fuel-burning appliance (installed at head level)
CO ALARM
HEAD
LEVE
• 08 •
NOTE: Due to the product's unique design and unfixed installation, it is not recommended to install it on a ceiling, as it is prone
to falling off and causing injuries to people.
Locations
to Avoid
Important
Note
mproper ocation can affect the sensitive electronlc components in this alarm. To avoid causing damage to the unit, to provide
optimum performance and to prevent unnecessarynuisance alarms,do not locate CO alarms in the fol lowing areas:
1. n garages or in any extremely dusty, dirty or greasyareas.
2. Where there is the possibility of smoke or fumes under normal operating circumstances.
3. n poorly ventilated kitchens,garages and furnace rooms. Keepthe COalarms at least 1.5m (5 feet) from potential smoke or
fume sources (e.g.stoves,furnaces,water heaters,space heaters)if possible.
4 In areaswhere a I _5m (5-foot) distance from a potential smoke or fume source is not possible.In modular, mobile or smaller
houses, it is recommended the CO alarm be placed asfar from any potential smoke or fume sources.
5. Within 1.5m (5feet) of any cooking appliance.
• 09 •