GB
6) OVERLOAD PROTECTION AND OVERHEAT PROTECTION
LED LOAD INDICATOR
The LED Load Indicator will flash green whenever the machine is plugged in (but not running), to indicate that
the machine is energized.
It will glow solid green when it is running with the load within the normal range.
OVERLOAD WARNING SYSTEM
When the load approaches overload conditions, the LED Load Indicator will flash red, and the motor may begin
to slow down.
OVERLOAD
If the excessive load is sustained too long, the motor will stop, and the LED Load Indicator will glow solid red.
Also, the "E01" error code will be displayed on the Information Screen. In this case, the motor must be restarted.
OVERHEAT THERMAL PROTECTION
If the temperature of the motor gets too high, the thermal protection system will stop the motor, and the LED
Load Indicator will glow solid red.
The "E02" or "E08" error code will be displayed on the Information Screen. Allow cooling water to flow through
the motor to bring the temperature down before continuing.
CAUTION: The motor will be damaged if it is repeatedly overloaded or overheated.
Always cool the motor by allowing cooling water to run through the motor for a few minutes whenever it
stops from either overheat or overload.
REBOOTING THE SYSTEM
In cases where the tool becomes unresponsive to any button inputs on the control panel, the system must
be rebooted. This occasionally occurs when there is heavy vibration or overload. To reboot, simply unplug the
power supply cord and wait for about 60 seconds (to allow the capacitors to discharge), then plug back in to
restart the system.
7) SAFETY CLUTCH
This machine is equipped with a mechanical clutch to protect the operator and machine from excessive