External wire and device fuse rating
Time to readiness, maximum
Switching frequency, maximum
Open / close cycle (motor), minimum
Minimal average cycle time (with continuous operation)
Utilisation category DC-12
Electrical fuse rating, maximum
Electrical data - Control inputs Guard locking function
Designation, Control inputs
Switching thresholds of the control inputs
Classification ZVEI CB24I, Sink
Classification ZVEI CB24I, Source
Current consumption at 24V, minimum
Current consumption at 24V, maximum
Allowable discrepancy time (input), maximum
Test pulse interval, maximum
Test pulse duration, maximum
Permissible residual drive current
Electrical data - Safety digital outputs
Designation, Safety outputs
Design of control elements
Voltage drop U
, maximum
d
Leakage current I
, maximum
r
Voltage, Utilisation category DC-12
Current, Utilisation category DC-12
Voltage, Utilisation category DC-13
Current, Utilisation category DC-13
Test pulse interval, typical
Test pulse duration, maximum
Classification ZVEI CB24I, Source
Classification ZVEI CB24I, Sink
Electrical data - Diagnostic outputs
2A gG
1.500 ms
0,3 Hz
3
20 s
24 VDC / 0,05 A
2 A
E1 und E2 (p-schaltend), E3 (n-schaltend)
−3 V ... 5 V (Low)
15 V ... 30 V (High)
C0
C1
C2
C3
5 mA
10 mA
10 s
40 ms
5 ms
1,5 mA
Y1 und Y2
kurzschlussfest, p-schaltend
2 V
0,5 mA
24 VDC
0,25 A
24 VDC
0,25 A
1000 ms
0,5 ms
C2
C1
C2
8-32