Herunterladen Inhalt Inhalt Diese Seite drucken

Package Contents; Safety Instructions - Renkforce 1341306 Bedienungsanleitung

Funk-thermometer
Inhaltsverzeichnis

Werbung

Verfügbare Sprachen

Verfügbare Sprachen

G Operating instructions
Wireless Thermometer
Item no. 1341306
Intended use
The product is used to display the time, the date, the weekday, and the indoor and out-
door temperature. The enclosed outdoor sensor transmits the measured temperature
wirelessly by radio to the base station.
The base station receives the DCF signal and uses it to set the time and date automati-
cally. However, it can also be set manually wherever there are reception problems.
Operation of the base station and outdoor sensor requires two batteries each of the
type AAA/Micro.
Always observe the safety instructions and all other information included in these op-
erating instructions.
Any use other than as described above is not permitted and can damage the product.
In addition, it can lead to hazards such as short-circuiting, fire, etc.
This product complies with the applicable National and European requirements. All
names of companies and products are the trademarks of the respective owners. All
rights reserved.
Package contents
• Base station
• Outdoor sensor
• Operating instructions
Explanation of symbols
This symbol points to specific risks associated with handling, function or
operation.
The "arrow" symbol points to special tips and operating information.
Safety instructions
D amage due to not following these operating instructions will void the
warranty! We do not assume any liability for any resulting damage!
W e do not assume any liability for material and personal damage caused
by improper use or non-compliance with the safety instructions! In such
cases, the warranty will be null and void.
• The unauthorised conversion and/or modification of the product is not
permitted for safety and approval reasons (CE). Never open/dismantle it
(except as described in these operating instructions for inserting/replac-
ing the batteries).
• Do not use this product in hospitals or medical institutions. Although the
outdoor sensor emits only relatively weak radio signals, these may lead
to the malfunction of life-supporting systems. The same may also apply to
other areas.
• The manufacturer is not responsible for incorrect displays or measured
values and any consequences which may arise thereof.
• The product is intended for private use and not suited for medical pur-
poses or informing the public.
• The product is not a toy and does not belong in the hands of children. The
product contains small parts, glass (display) and batteries. Position the
product so it is out of the reach of children.
• The base station is only suitable for dry, enclosed indoor areas. Do not ex-
pose the product to direct sunlight, strong heat, cold, humidity or moisture;
otherwise it may be damaged.
• The outdoor sensor is suitable for use in protected outdoor areas. It must
not be used in or under water, this will destroy it.
• Do not leave packaging material carelessly lying around, as it could be-
come a dangerous plaything for children.
• Handle the product with care; it can be damaged by impacts, blows, or
accidental falls, even from a low height.
• If you have any questions that are not answered in these operating in-
structions, please contact our technical department or another specialist.
Battery/rechargeable battery instructions
• Batteries/rechargeable batteries must be kept out of the reach of children. Do not
leave batteries lying around. There is a danger that children or pets may swallow
them, danger to life! If they are swallowed, consult a doctor immediately.
• Make sure that rechargeable batteries are not opened, short-circuited or thrown
into a fire, as there is a risk of explosion.
• Check that the polarity is correct when inserting the batteries/rechargeable batter-
ies (pay attention to plus/+ and minus/-).
• Chemical liquid may leak out of spent or overaged batteries, which may damage the
device. Acid contact due to leaking or damaged single/rechargeable batteries can
burn your skin, therefore use suitable protective gloves.
• Do not mix single-use batteries with rechargeable batteries.
• Do not mix single-use/rechargeable batteries with different charge levels (e.g., full
and half-full batteries/rechargeable batteries).
• Always replace the entire set of batteries/rechargeable batteries and never just
individual cells.
Controls of base station
1
"+" button
2
"SNOOZE/LIGHT" button
3
"-" button
4
"CHANNEL" button
5
Battery compartment
6
"RESET" button
7
"MODE" button
8
"ALARM" button
Getting started with the outdoor sensor
• Slide the battery case lid on the back of the outdoor sensor downwards and out.
• In the battery compartment is a sliding switch for setting the transmission channel. If
you are using only the single outdoor sensor enclosed, set the switch to channel 1.
If more than one outdoor sensor is reported to the base station (up to 3 are possible),
you must set each outdoor sensor to a different channel.
• Insert two AAA/Micro batteries into the battery compartment paying attention to the
correct polarity (observe positive/+ and negative/-).
• Close the battery compartment again.
Getting started with the base station
• Open the battery compartment of the base station.
• Insert two AAA/Micro batteries into the battery compartment paying attention to the
correct polarity (observe positive/+ and negative/-).
• Close the battery compartment again.
• Immediately after the batteries are inserted, the base station briefly shows all dis-
play segments. Then, the first indoor temperature reading appears in the bottom left
of the display.
• The base station will now initiate the search for the signal of the outdoor sensor; the
reception icon on the bottom right of the display flashes. The search process lasts
approx. 3 minutes. Do not press any button during this time. Do not move the base
station.
The outdoor sensor should be placed nearby the base station (distance 0.5 to 1 m)
during this stage.
• If the base station still does not display any outdoor sensor temperature data after
3 minutes (the bottom right of the display shows dashes, but no temperature value),
you can perform a new search for the outdoor sensor at a later stage (after receiv-
ing the DCF signal).