Herunterladen Inhalt Inhalt Diese Seite drucken

Standard, 24; Technical Data; [Eex Ia] Iic, 24; Function - Camille Bauer SINEAX TV 808-115 Betriebsanleitung

Trennverstärker
Inhaltsverzeichnis

Werbung

Verfügbare Sprachen

Verfügbare Sprachen

(10)
(2)
(6)
Cami l l e Bauer AG
CH-561 0 Wohl e n
Swi t zerl a nd
ON
(12) (5)
(11)
Fig. 2
(2)
Front plate
(5)
Type label
(6)
Transparent cover
(7)
Fixing bracket
(8)
Opening for withdrawing clip (for opening the housing)
(9)
Top-hat rail 35 ×15 mm or 35×7.5 mm (EN 50 022)
(10)
Terminals
(11)
Terminals
(12)
Space for notes
ON
Green LED for indicating device standing by

6. Technical data

Measuring input
DC current:
Standard ranges 4...20 mA
Limit values
0...0.1 to 0...40 mA
also live-zero,
start value > 0 to ≤ 50% fi nal va-
lue
– 0.1...0...+ 0.1 to
–20...0...+ 20 mA
max. span: ≤ 40 mA
also bipolar asymmetrical
R
DC voltage:
Limit values
0...0.06 to 0...40,
also live-zero,
start value > 0 to ≤ 50% fi nal va-
lue
– 0.06...0...+ 0.06 to
–20...0...+ 20 V,
max. span: ≤ 40 V
R
Overload:
DC current
continuously 2-fold
DC voltage
continuously 2-fold
12
(7)
(8)
(9)
without

function

ON
= 15 Ω
i
= 100 kΩ
i
Measuring output
DC current:
Standard ranges
4...20 mA, 0 ... 20 mA
invert
20 ... 4 mA, 20 ... 0 mA
Burden voltage/
external resistance:
Standard version,
20 V / R
Ex version,
15 V / R
Current limiter at
R
max.:
Approx. 1.1 ×I
ext
Voltage limiter
at R
= ∞:
Approx. 26 V
ext
Residual ripple in
output current:
< 0.5% p.p.
Response time:
< 50 ms
Power supply H
AC/DC power pack (DC and 45...400 Hz)
Table 1: Nominal voltages and tolerances
Nominal voltage U
Tolerance
N
24... 60 V DC/AC
DC – 15...+ 33%
1
85...230 V
DC/AC
AC ± 15 %
24... 60 V DC/AC
85...230 V AC
± 10%
85...110 V DC
– 15 ... + 10%
1
For power supply > 125 V, the auxiliary circuit should include an
external fuse with a rating ≤ 20 A DC.
Power input:
≤ 1.2 W resp. ≤ 3 VA
Accuracy data (acc. to DIN/IEC 770)
Basic accuracy:
Limit error ≤ ± 0.2%
Including linearity and reproduci-
bility errors
Installation data
Terminals:
DIN/VDE 0609
Screw terminals with wire guards,
for light PVC wiring and
max. 2 ×0.75 mm
Permissible vibrations: 2 g acc. to EN 60 068-2-6
Shock:
3 ×50 g
2 shocks each in 6 directions acc.
to EN 60 068-2-27
Electrical insulation:
All circuits (measuring input/mea-
suring output/power supply) are
electrically insulated
max. 1000 Ω
ext
max. 750 Ω
ext
AN
Instruments
version
Standard
(Non-Ex)
In
type of
protection
intrinsically safe
[EEx ia] IIC
2
2
or 1 × 2,5 mm

Werbung

Inhaltsverzeichnis
loading

Inhaltsverzeichnis