CLEANING
Turn manually the conveyor until the shaft pin "27" coincides with the joint
notch "34".
Unloose first the counter nut and then the joint fixing screw, using a 10 key;
let the joint slide towards the conveyor bench "31" disengaging the joint
parts.
Lift up the entry and exit lower diffusers "1" at max. opening.
Lift up the conveyor bench "31" from both sides and move it towards the
control side.
Open the serigraph. panel "23" and, using a pair of strong gloves to avoid
accidents, disengage the diffusers "3" and "25" from the supports which are
near the door, turning upwards; then bring the diffusers towards the centre
of the door and remove it.
In case of model
DPZ3030E
, the diffusers are not engaged but they
are fixed with hexagon nuts; use a 10 key to unscrew the nuts.
To clean the disassembled parts see chapter 9.1; to clean the backing
chamber inside, remove the accumulation of dirt with a burst and a dustpan
or use a vacuum cleaner; clean the metal surfaces with a sponge steeped in
water or non abrasive - corrosive detergents then rinse the surfaces with a
damp sponge.
At the end of cleaning remount all the components in opposite sequence to
the above mentioned description.
It is advisable to clean the backing chamber every 200 operating hours.