VIKING YouSafe
4.
When the suit is dry, repack the immersion suit in
accordance with instructions or keep it on a wide
hanger.
5. PACKING THE SUIT (Figure 3)
1. Place the suit flat on the floor. Unzip.
2. Fold up the feet to the crotch.
3. Fold the legs up over the feet.
4. Fold the sleeves across the chest.
5. Place the suit into the bag.
6. PACKING OF AUXILIARY MEANS OF BUOYANCY
(photo 4.1-4.6)
1. Remove release strap.
2. Close zipper from right side.
3. Fold buoyancy chamber and close zipper partly. Stop
right after the yellow part of the zipper.
4. Carefully pull the string through the yellow part of
the zipper. Make sure the zipper stays closed.
5. Close zipper.
6. Bend zipper ends into the cover. Attach release strap
again.
Hurricane (PS4190) / VIKING YouSafe
TM
Hurricane+ (PS4191)
TM
7. REPLACEMENT OF CO
CYLINDER AND GASKET (figure
2
A. After immersion in water, the immersion suit
with the auxiliary means of buoyancy is to be
rinsed in fresh water. Leave it on a hanger until
it is completely dry. Empty the auxiliary means of
buoyancy of air through the oral-inflation valve.
B. Unscrew and discard the used CO
C. If the release arm (3) has been pulled, push it back in
place and attach the lock pin (4) above the release
arm.
D. The gasket (2) under the CO
removed and discarded.
E. Insert a new gasket in the inflator (5). Place it right
at the bottom of the inflator.
F. Screw the CO
-cylinder (1) tightly onto the inflator
2
(5) by hand.
EN
5)
cylinder (1).
2
cylinder must be
2
9