Herunterladen Inhalt Inhalt Diese Seite drucken

Pages; Operating Instructions; Description Of The Unit; Key Facts In Brief - STIEBEL ELTRON DHC 3 U Gebrauchs- Und Montageanweisung

Geschlossene kleindurchlauferhitzer
Vorschau ausblenden Andere Handbücher für DHC 3 U:
Inhaltsverzeichnis

Werbung

Verfügbare Sprachen

Verfügbare Sprachen

Fig. 2
Type
Power*
DHC 3
3,0 kW
DHC 3 U
3,5 kW
DHC 4
4,4 kW
DHC 6
6,6 kW
DHC 6 U
6,6 kW
DHC 8
8,8 kW
* 230 V Volt supply
Table 1
20
2
1
Temperature increase
2 l/min
4 l/min
6 l/min
22 °C
11 °C
7 °C
25 °C
13 °C
8 °C
32 °C
16 °C
11 °C
_
24 °C
16 °C
_
24 °C
16 °C
_
32 °C
21 °C

Operating Instructions

(for the user and the qualified installer)
Legend to Figure 2
1 "Power" light
2 "Overheating" light
overheating

Description of the unit

The DHC hydraulically-controlled
instantaneous water heater heats the
water while it is flowing through the unit.
The heating power is switched on
automatically in the event of the minimum
flow rate being exceeded. The "Power"
light (Fig. 2, Item 1) indicates that the
heating system is switched on.

Key facts in brief

The DHC is equipped with an overheating
protection system. In the event of
overheating, the heating power will be
switched off, and the "Overheating" light
(Fig. 2, Item 2) will come on. After a
cooling-off phase, the unit will automati-
cally switch the heating power back on,
and the "Overheating" light will go out. If
the unit is overheating, this indicates that
the incoming water volume is too small
The outlet temperature can be reduced by
increasing the flow rate or by mixing in
cold water. The hot water output depends
on the capacity of the unit, the cold water
temperature, and the flow rate.
8 l/min
10 l/min
5 °C
4 °C
Table 1 shows the temperature rise of
particular units as a function of the flow
6 °C
5 °C
rate. If these volumes are added to the
8 °C
6 °C
cold water temperatures which prevail at
the installation location, the particular hot
12 °C
10 °C
water temperature in each case can be
obtained.
12 °C
10 °C
16 °C
13 °C
Care
A damp cloth is all that is needed to look
after the housing of the unit. Do not use
any effervescent cleaning agents or agents
with a potentially solvent effect.
carried out by a qualified installer. Page
28 provides a summary of faults which
you can deal with yourself.
Unit is heating up
Unit is
Open the fitting wider.
Maintenance
Maintenance work may only be

Quicklinks ausblenden:

Werbung

Inhaltsverzeichnis
loading

Diese Anleitung auch für:

Dhc 3Dhc 4Dhc 6Dhc 8Dhc 6 u

Inhaltsverzeichnis