Technical specifications
5.1
Transport and storage conditions
The requirements regarding transport and storage conditions for the device are more
stringent than those laid down in IEC 611312. The following requirements apply to the
transport and storage of the device in its original packaging.
The climatic conditions conform to the following standards:
● IEC 60721-3-3, Class 3K7 for storage
● IEC 60721-3-2, Class 2K4 for transport
Mechanical requirements conform to EC 60721-3-2, Class 2M2.
Type of condition
Drop test (in transport package)
Temperature
Atmospheric pressure
Relative humidity
Sinusoidal vibration in accordance with
IEC 60068-2-6
Shock in accordance with IEC 60068-2-29
Proper transport and storage, installation and assembly as well as careful operation and
maintenance are prerequisites for a trouble-free and safe operation of the device.
Non-compliance shall result in the voiding of the device warranty.
5.2
Notes about usage
The device is designed for industrial use.
The same mechanical and climatic operating conditions of the PRO device apply to which
the extension unit was installed.
Extension Units
Operating Instructions (Compact), 02/2009, A5E02296499-01
Permitted range
≤ 1 m
From –20 to +60° C
From 1 140 hPa to 660 hPa,
corresponds to an elevation of –1 000 to 3 500 m
From 10 to 90%, without condensation
5 to 9 Hz: 3.5 mm
9 Hz to 500 Hz: 9.8 m/s
2
250 m/s
, 6 ms, 1000 shocks
2
5