Herunterladen Diese Seite drucken

IFM Electronic efector800 VSE001 Montageanleitung Seite 16

Werbung

Verfügbare Sprachen

Verfügbare Sprachen

Wiring:
Terminal Connection Description
1
Supply L+
2
Supply L-
3
OUT 1
4
OUT 2
5
IN 1
6
GND 1
7
IN 2
8
GND 2
9...12
connections to the sensor 1 (type VSAxxx or ICP sensor):
9
L+ (9 V)
10
I out (10 V)
11
GND
12
self-test
16
1
BN
21
2
WH
22
3
BU
23
4
BK
24
1
BN
17
2
WH
18
3
BU
19
4
BK
20
1
BN
13
2
WH
14
3
BU
15
4
BK
16
supply 10...32 V DC
for ICP sensor: 18...30 V DC
GND
output early warning (max. 100 mA,
NC/NO programmable)
or: analogue value 0/4...20 mA
output main alarm (max. 100 mA,
NC/NO programmable)
actual speed value 1 (0/4...20 mA or pulse)
actual speed value 1 (GND)
actual speed value 2 (0/4...20 mA or pulse)
actual speed value 2 (GND)
at the sensor: pin 1 (brown)
at the sensor: pin 2 (white)
at the sensor: pin 3 (blue)
at the sensor: pin 4 (black)
1
L+ (10...32 V DC)
2
L-
3
OU 1: switch/analog
4
OU 2: switch
5
IN 1 (0/4...20 mA / pulse)
6
GND 1
7
IN 2 (0/4...20 mA / pulse)
8
GND 2
BN
1
9
WH
2
10
BU
3
11
BK
4
12

Werbung

loading