Herunterladen Diese Seite drucken

WIKA 700.01.80 Betriebsanleitung Seite 5

Werbung

Verfügbare Sprachen

Verfügbare Sprachen

3. Technical data and intended use
3. Technical data and intended use
Static pressure / Overpressure safety maximum
Model
Pressure ranges
Model 700.01:
0 ... 400 mbar to 0 ... 10 bar
Typ 700.02:
0 ... 160 mbar and 0 ... 250 mbar
0 ... 400 mbar and 0 ... 2.5 bar
Pressure connection
T
According to the general technical regulations for pressure gauges,
respectively (i.e. EN 837-2 "Selection and installation recommendations for
pressure gauges").
When screw-fitting the gauges the force required for sealing must not be
applied through the case or terminal box but, using a suitable tool, only through
the spanner flats provided for this purpose at the square of the connector.
IP Ingress protection
IP 54 per EN 60 529 / IEC 60 529
Permissible vibratory stress at the mounting location
T
As a matter of principle the instruments should only be mounted at locations
without vibratory stresses
T
Where required, a decoupling from the mounting location can be achieved
e.g. by a flexible connecting line from the measuring point to the pressure
gauge and mounting via a measuring instrument bracket.
T
If this is not possible, the following limits must not be exceeded:
Frequency range < 150 Hz
Acceleration < 0.7 g (7 m/s
WIKA Operating instructions pressure gauges Model 700.0X with 851 per ATEX
Working pressure
max.
(static pressure)
optionally 100, 250
or 400 bar
50 bar
100 bar
)
2
Overpressure safe
GB
either side
to maximum
working pressure
50 bar
50 bar
5

Werbung

loading

Diese Anleitung auch für:

700.02.80