4.2 General data
KACO
General data
Max. Efficiency
Europe. Efficiency
Self consumption: Standby
Feed-in from
Transformer unit
Protection class / over voltage
category
Grid monitoring
Distribution system
Display
Controls
Menu languages
Interfaces
Communication
Radio technology
Frequency spectrum
Antenna gain
Potential-free relay
DC isolator switch
AC isolator switch
Cooling
Number of fans
Noise emission
Housing material
H x W x D
Weight
Interference immunity /
interference
Emission / grid feedback
Certifications
4.3 Environmental data
KACO
Installation height
Installation distance from coast
Ambient temperature
Ambient temperature (storage)
Power derating from
Protection rating (KACO installation
location)
Humidity range (non-condensing)
[%]
Pollution level inside the enclosure
Pollution level outside the
enclosure
KACO blueplanet 50.0 NX3 M5 / KACO blueplanet 60.0 NX3 M5
blueplanet 50.0 NX3 M5 WM OD IIG0
TN-C system, TN-C-S system, TN-S system, TT system
USB (Connect-NX), RS485 (Smart meter / Datalogger), RJ45 (Ripple control receiver/
WiFi, LAN, Ethernet, Modbus TCP-IP in reference to SunSpec / $
Sunspec Modbus RTU, KACO Legacy Protocol
640 mm × 670 mm × 298 mm
EN 61000-6-1, EN 61000-6-2, EN 62920 - Class A /
EN 61000-6-3, EN 61000-6-4, EN 62920 - Class B, EN 55011 - group 1 Class B /
EN 61000-3-11, EN 61000-3-12
Overview: see homepage, download area
blueplanet 50.0 NX3 M5 WM OD IIG0
blueplanet 60.0 NX3 M5 WM OD IIG0
98.2 %
97.6 %
< 1 W
> 100 W
no
I / II (AC) II (DC)
Country-specific
LEDs
APP
EN; DE
NA-Protection device)
WLAN 802.11 b / g / n
2,412 MHz – 2,472 MHz
3.4 dBi
yes (integrated switch)
yes
no
Air cooling
3x outside, 2x inside
55 dB(A)
AL
< 43 kg
blueplanet 60.0 NX3 M5 WM OD IIG0
3000 m
> 500 m
- 25 °C – + 60 °C
- 25 °C – + 60 °C
> 45 °C
IP 66 / NEMA 4X
100 %
2 (reduced by IP 66 Housing)
3