4 Technical data
4.1 Electrical data
KACO
PV Input
Max Recommended PV Array Power
Mpp voltage range at Pnom
Operating voltage range
Nominal DC voltage
Start voltage
Max PV voltage
Nominal PV current (Inom)
1
Number of strings per MPP controller
Number of MPP controls
Max PV current (Isc)
2
Input source feedback current
Polarity safeguard
String fuse
DC overvoltage protection
KACO
Grid Port
Max Grid Output Power
Nominal Grid Voltage
Grid Voltage Range
Rated current @ 220 / 380 V
Rated current @ 230 / 400 V
Rated current @ 240 / 415 V
Max Grid Output Current
Contribution to peak short-circuit current ip
Initial short-circuit alternating current (Ik"
first single period effective value)
Short-circuit current continuous (lk. max
output fault current)
Inrush current
Nominal Grid Frequency
Frequency Range
Reactive power
Power Factor Range
Number of feed-in phases
Harmonics THD
Max. voltage range (up to 100 s)
AC overvoltage protection
1
The "Nominal PV Current (Inom)" the maximal theoretical value for operation with full power when the feed-in power
is low. The device is limited to the maximum AC power.
2
The "Max PV Current (Isc)" together with the open circuit voltage (U
PV generator. This is the relevant value for string design and represents the absolute maximum limit for inverter
protection. The connected PV generator must be designed in such a way that the maximum short-circuit current is less
than or equal to the I
SCmax
circuit current greater than the I
Page 87
blueplanet 50.0 NX3 M5 WM OD IIG0 blueplanet 60.0 NX3 M5 WM OD IIG0
blueplanet 50.0 NX3 M5 WM OD IIG0 blueplanet 60.0 NX3 M5 WM OD IIG0
of the inverter under all foreseeable conditions. The design must in no case result in a short-
of the inverter.
SCmax
75000 Wp
500 – 850 V
200 - 1000 V
630 V
250 V
1100 V
40 A (PV1) / 32 A / 32 A / 40 A (PV4) / 32 A
2
5
60 A (PV1) / 48 A / 48 A / 60 A (PV4) / 48 A
0 A
yes
no
Type II
50.0 kVA
220 / 380 V [3/N/PE]
230 / 400 V [3/N/PE]
240 / 415 V [3/N/PE]
180 – 305V
75.8 A
72.5 A
69.4 A
83.6 A
200 A
83.6 A
83.6 A
<20 % of the rated AC current for a maximum of 20 ms
50 / 60 Hz
45 – 65 Hz
0 – 60 % Snom
0.8
– 0.8
cap
3
< 3 %
305 V (Phase - Neutral)
Type II
) defines the characteristic of the connected
OCmax
KACO blueplanet 50.0 NX3 M5 / KACO blueplanet 60.0 NX3 M5
90000 Wp
60.0 kVA
91.0 A
87.0 A
83.3 A
95.3 A
95.3 A
95.3 A
ind