LED indicators on access point
Underneath the display 6 for displaying the status codes,
there are three LED indicators which signal the system status.
LED
No.
Indications
Meaning
3
green
Continuous
Access point ready for
light
operation
4
yellow
Intermittent
Ethernet connection
flashing
5
blue
Continuous
At least one existing Blue-
light
tooth connection
System Reset (see figure P)
1st possibility:
– Interrupt the power supply.
Note: All screwdriving data will be lost if emergency power
supply (factory setting: off) is not active. Please save
first.
2nd possibility:
– "Reset" via Service-Tool (see Service-Tool instructions).
3rd possibility:
– Remove the maintenance cover plate 8 (see "Connection
Work", page 26).
– Press the reset button 17 for at least 3 seconds.
The system will reboot as soon as the LED indicators go out
(approx. 20 seconds).
Note: Do not "reset" again during the boot sequence. The op-
erating system could become damaged.
Putting the I/O Module into Operation
If the I/O module is supplied with 24 V via the access point, it
will automatically switch on when the access point is switched
on.
If the I/O module is supplied by an external power supply unit,
it should be switched on before the access point or at least at
the same time as the access point because the access point
may have to send initial commands to the I/O module during
boot-up.
LED indicators on I/O module
Underneath the display 6 for displaying the status codes,
there are two LED indicators which signal the system status.
LED
No.
Indications
Meaning
32
green
Continuous
light
31
red
Communication error
– Incorrect wiring of the RS422 in-
terface
– Incorrect configuration of the
baud rate in the access point setup
– Firmware of access point and I/O
module do not match
Bosch Power Tools
BT-EXACT/BT-ANGLE EXACT screwdriving system
The BT-EXACT/BT-ANGLE EXACT screwdriving system ena-
bles wireless data transfer of screwdriving signals using Blue-
tooth wireless technology.
OK and NOK signals (screw connection OK/not OK) of the pro-
duction cordless screwdrivers in the BT-EXACT and BT-
ANGLE EXACT series are transmitted to the access point.
Without the access point, screwdrivers in the BT-EXACT and
BT-ANGLE EXACT series cannot be put into operation: The
screwdrivers are locked when they are delivered and can be
unlocked only by the access point.
– First put the access point into operation.
Status codes
All status codes are shown both in the display 6 of the access
point and in the monitor program.
Error codes which refer to a failure or unavailability of the ac-
cess point are displayed only in the monitor program.
If several status codes are present simultaneously, they are
cycled through in intervals of two seconds.
The status codes are divided into the following groups:
– Warnings
– Non-critical errors
– Critical errors
– Log-specific errors
I/O module ready for
operation
English | 33