LocalNet RS 232 Interface
Safety
Danger from incorrect connection to the power source.
This can result in damage to the PC.
General
The LocalNet RS 232 interface can only be used in conjunction with LocalNet application
software and system components (power source, wire-feed unit, etc.) with LocalNet con-
nection sockets. To ensure correct operation, the LocalNet application software must al-
ready be running on the computer.
Scope of supply
(1)
Description of the
Each display represents a transmit line (TxD) and a receive line (RxD). A flashing display
displays on the
indicates that data is being transferred along the respective lines.
LocalNet RS 232
interface
x ... Display flashes
RS 232
TxD
x
x
-
-
-
10
CAUTION!
Connect the power source to the PC using the LocalNet RS 232 interface and the
cables provided only.
(2)
LocalNet
RxD
TxD
RxD
x
x
x
-
x
x
-
-
x
x
x
-
-
-
-
(1)
LocalNet RS 232 interface
(2)
LocalNet interface cable
(3)
RS 232 interface cable
(4)
(4)
Software tools CD
(3)
Status
Communication is ok
PC does not respond; start the LocalNet application
software on the PC
Interface error; connect to PC and check system com-
ponents. Replace interface if necessary.
PC is sending data - system component does not re-
spond; system component possibly faulty
No display flashing; check connection to PC and system
component. Replace interface if necessary