Herunterladen Diese Seite drucken

T.I.P. EXTREMA 500/13 IX Gebrauchsanweisung Seite 13

Schmutzwasser-tauchpumpe

Werbung

Verfügbare Sprachen
  • DE

Verfügbare Sprachen

  • DEUTSCH, seite 3
given in the technical data chart can be achieved. However, the pump must be constantly monitored to avoid dry
running.
5.5.
How to position the pump
When positioning the pump, please make sure that the max. submersion depth indicated in the technical data will
not be exceeded. Likewise, please make sure that the minimum self-priming level is not fallen short of. If
everything is properly set, the water level may decrease down to the minimum suction level once the pump is
operating. Please position the pump on solid ground. Avoid placing it on lose stones or sand. When positioning
the pump, please do make sure that the pump cannot tip over or sink into the ground with its intake openings (6).
The penetration of sand, mud or comparable matters is to be avoided. To position, lift up or carry the pump,
please use only the carrying handle. If required for lowering or raising the pump, you may connect a suitable
lowering rope to the carrying handle. In no case must the pressure hose, the mains cable or the cable of the
floating switch be used to position, to lift up or to carry the pump.
6. Electrical connection
The unit is equipped with a mains connection cable and a mains plug. It must only be replaced by qualified staff to
avoid any danger. Please do not use the mains connection cable to carry the pump, and do not use this cable to
pull off the plug from the socket, either. Protect the mains connection cable and mains plug from heat, oil or sharp
edges.
The values stated in the technical details have to correspond to the mains voltage. The person
responsible for the installation has to make sure that the electrical connection is earthed in
compliance with the applicable standards.
The electrical connection has to be equipped with a highly sensitive residual current circuit-
breaker (FI switch): ∆ = 30 mA (DIN VDE 0100-739).
If extension cables are used, their cross-section must not be smaller than that of rubber-
sheathed cables of the H07RN-F (3 x 1.0 mm²) short code. The mains socket and the plug-
and-socket elements have to be in splash-water-proof design.
The system impedance for supply systems used for the connection of pumps equipped with a
1600 W motor is limited to a maximum of 0.416 ohms. If necessary, please enquire your
system impedance from your utilities provider.
7. Putting into operation
Nobody must be in the water while the pump is running.
The pump must only be operated in the performance range indicated on the type plate.
Dry-running - i.e. operating the pump without discharging water - is to be avoided since the
absence of water may cause the pump to run hot. This may cause considerable damage on
the device.
Please make sure that the electrical plug connections are in the flood-proof area.
As long as the device is connected to the electrical mains, one must never reach with one's
hands into the opening of the pump.
Please inspect the pump visually prior to each use. This applies in particular to the mains connection line and the
mains plug. Make sure that all screws are firmly tightened, and verify the perfect condition of all connections. A
damaged pump must not be used. In any case of damage, the pump has to be inspected by qualified service
staff. Each time the pump is put into operation, please make sure that the pump is set up securely and firmly
standing. To put the unit into operation, please plug the mains plugs into a 230V AC socket. If the water level has
reached or exceeded the cut-in level, the pump will start to run immediately. To stop the operation of the pump,
please pull the mains plug off the socket. The electrical pumps of the T.I.P. EXTREMA series are equipped with
an integrated thermal motor protection feature. In the case of overload, the motor will switch off independently and
on again after cooling down. For possible causes and their elimination, please refer to the "Maintenance and
4
11

Werbung

loading