Step 2
Screw the sensor into the
adapter. Avoid mechanical influ-
ence on the sealing chamfers.
Step 3
Clamp sensor and adapter into a
clamping device (D). The sealing
chamfers (E) must not be dam-
aged. Tighten the sensor with a
spanner until you can feel the
end stop.
Note: If you continue to turn,
this can have adverse effect on
the sealing.
Electrical connection
The unit must be connected by a suitably qualified electrician.
The national and international regulations for the installation of
electrical equipment must be observed.
Voltage supply to EN50178, SELV, PELV.
Disconnect power before connecting the unit as follows:
2 wire connection
1
BN
2
WH
4
BK
3
BU
Core colours of ifm sockets:
1 = BN (brown), 2 = WH (white),3 = BU (blue), 4 = BK (black);
n.c. = not connected.
3 wire connection
L +
L-
n.c.
n.c.
1
BN
L +
2
WH
4
BK
n.c.
3
BU
L-
D
E
Connector view
(sensor)
1
4
2
3