Function and features
The pressure sensor detects the system pressure and converts it into
an analogue output signal (4 ... 20 mA). The measuring range can be
scaled to up to 25% of the value of the measuring range (→ page 19).
It is also indicated:
• System pressure above the measuring range: output signal > 20 mA.
• System pressure below the measuring range: output signal drops to
max. 3.2 mA (depending on the scaling).
Applications (Type of pressure: relative pressure):
Order no.
bar
PM2053
PSI
MPa
bar
PM2054
PSI
kPa
bar
PM2056
PSI
kPa
mbar
PM2057
PSI
kPa
Avoid static and dynamic overpressure exceeding the given over-
load pressure.
Even if the bursting pressure is exceeded only for a short time
the unit can be destroyed (danger of injuries)!
The unit is ready for operation when delivered.
Factory preset: not scaled (ASP = 0 bar; AEP = 100% of the final value
of the measuring range).
Measuring
range
-1.0 ... 25
-15 ... 363
-0.1 ... 2.5
-0.5 ... 10
-7 ... 145
-50 ... 1 000
-0.13 ... 2.50
-1.8 ... 36.3
-13 ... 250
-50 ... 1 000
-0.7 ... 14.5
-5.0 ... 100
Permissible
overl. pressure
100
1 450
10
50
725
5 000 (5 MPa)
20
290
2 000 (2 MPa)
10 000 (10 bar)
145
1 000 (1 MPa)
Bursting
pressure
350
5 070
35
150
2 175
15 000 (15 MPa)
50
725
5 000 (5 MPa)
30 000 (30 bar)
450
3 000 (3 MPa)
13
1