Use with factory setting
Installation
Before mounting and removing the sensor, make sure that no pressure
is applied to the system.
The unit is adaptable for various
process fittings. ifm adapters to
be ordered separately as acces-
sories.
Mount adapter (B) to the sensor
first, then sensor + adapter to
the process connection by means
of a nut, a clamping flange or
similar (A).
If it is not possible to slide the fix-
ing element (A) down over the
top of the sensor: slide it up over
A
the bottom of the sensor before
B
the adapter is mounted.
Note: Sensor and adapter are only to be mounted once.
Mounting of the adapter
Step 1
Grease thread and sealing cham-
fer of the sensor and of the
adapter with the greasing paste
supplied.
The greasing paste is food-grade
(USDA-H1 84-201).
Make sure that the O-ring (C) is
correctly positioned.
C