Youcan program the following registers:
Register
Function
CVI
Loco address
CV2
Starting voltage
voltage for speedsetting 1 - if loco starts only ata higher
s eed settin
increase
value.
CV3
Acceleration 1 = fast, 255 = slow
CV4
Brakin
I = fast
255 - slow
Hint: When programming with the 55015 Universal Remote, the following CVsare
programmed by input of the number of the desired CVin CV6 and then input of the desired
function value in CV5(see example below).
CV5
Max. voltage
Voltagefor highest speed step- if a lower top speed is desired,
decrease value.
CV5
after input of CV6
function
value for CV to be
ro rammed
CV6
CV to be
ro rammed
CV29
NMRA configuration
Bit programming
Bit 1: direction, 0 = normal, 1 = reversed[01
Bit 2: speed steps, O= 14 (LGB),2 = 28 [0]
Bit 3: analogoperation, O not possible, 4 = possible [4]
Bit 4: not used [0]
Bit 5: speed steps, 0 = factory-programmed,
16 = user-programmed[0]
Bit 6: address area,O= 0-127 (LGB),32 = 128-10039 [0]
To program,add the valuesfor the individual Bits and
program the resulting function value.
Hint: To program a loco to reversed direction of travel
(for example, F7 A-B-Acombination), program function
value 5.
Attention! Loco addresses 128-10039 and 28 speed steps
cannot
be used with LGB MTS .
Voltage for function terminal Fl
CV49
(depends on loco model, do not change, as functions
can be affected
or destro
ed
CV50
Volta
e for li htin
terminals
see CV49
CV51
Command
for function
terminal
Fl
O= lighting button 9
1
button 1 (buttons 2-8 not used)
9 = button 1 (buttons 2-8 used as well)
10 = button 2
11 = button 3
12 = button 4
13 = button 5
14 = button 6
15 = button 7
16 = button 8
64 = lighting button 9 (on only when loco is reversing)
65 = button 1 (on only when loco is reversing)
128 -
- lighting button 9 (on only when loco is moving forward)
129 -
- button 1 (on only when loco is moving forward)
18
(dependson loco model, do not change,as functions
can be affected
CV52
Command
Available
Factory
values
re-set
CV53
Command
00-22
3
CV54
LGB configuration
Bit programming
(0-255)
Bit 1: hand-offfunction,
Bit 2: MTS Back-EMF, O = off, 2
1-255
3
Bit 3: analog Back-EMEO= off, 4 = on [4]
Bit 4: not used [0]
1-255
3
Bit 5: O Fl constant, 16
Bit 6: 0 = F2 constant,32 = F2flashing
Bit 7: sound function (Oor 64)
Bit 8: sound function (Oor 128)
To program, add the values for the individual Bits and
(1-255)
[255]
program the resulting function value.The valuesfor
Bits 5-8 vary between locos. The values for your loco
can be readusing the 55045 MTS PCDecoderProgramming
Module.
Hand-off function on: When operating with 55015, you can
adjust direction and speed for two seconds after selecting a
movin
loco without
CV55
Reset factory pre-set values for CVs
Program:
6-55->
5-55*
CV56
Voltage for function terminal F2
(dependson loco model, do not change,as functions
can be affected
CV57
Command
CV58
Pausetime (analog operation) (0.5 secondsx function value) (0-255)
When the polarity of the analog track voltage is reversed,the
loco waits for the programmed time period, then accelerates
in the new direction
CV60
Back-EMF:Max. adjustmentfactor
Specifiesthe max. increaseor decreaseof voltage applied
during eachtime interval (programmedin CV61)
(1-32)
1
small steps, 255 = large steps
The factory pre-set values of CV60and CV61are optimized
for LGB motors.
1-32
CV61
Back-EMF: A djustment frequency
Specifieshow often per second the motor voltage is adjusted
accordingly,the loco will reactto curves and grades
immediately or with a short delay
0 = immediate
CV62
Back-EMF:Max.Adjustment
Limits the total adjustment in motor voltage. If there is a very
large load on the motor, the adjustmentwill not exceedthis
value- for more realistic operations,so that locos will slow a
bit on grades.
0 = no ad'ustment
CV67
Speedstepsprogrammed by user (see CV29):
28 speed stepsare programmed in CV67to CV94.
to
CV94
With LGB MTS,every secondvalueis skipped (14 speedsteps).
Factory pre-set speed steps:
7, 9, 11, 13, 16, 20, 24, 28, 32, 36, 42, 48, 54, 60, 68, 76, 84,
or destro
ed
for front li htin
terminal
see CV51
for rear li htin
terminal
see CV51
off, 1 = on [O]
on [2]
Fl flashing
causin
the loco to sto
(1-32)
or destro
ed
for function
terminal
F2
see CV51
(1-255)
(0-255)
ad'ustment
255 = maximum
dela
(0-255)
255 = maximum
ad'ustment
(0-255)
[128]
[641
[10]
[5]
[255]
19