SPECIFICATIONS
Model Name
Cabinet
Model
IEC Protection Class
Socket Outlet (Vehicle
Interface)
Voltage & Current Rating 400VAC 50/60 Hz - 3-phase 32A
AC Maximum Charging
Output
Built-in Residual Current
Sensing module
Required Circuit Breaker
on AC Grid
Required RCCB on AC
Grid
Required AC Grid Cord
RFID / NFC Module (Supported
models only)
Material
Dimension
Dimension (-T2S models)
Dimension (Packing)
Weight
AC Mains Cable Dimension
Protection Degree
Operating Condition
EVC02-AC22 / EVC02-AC22R
EVC02-AC22-T2S / EVC02-AC22R-T2S
EVC02-AC11 / EVC02-AC11R
EVC02-AC11-T2S / EVC02-AC11R-T2S
R => RFID Equipped Models
T2S => Type-2 Shuttered Socket
-6 => DC 6mA Fault current detection
EVC02
ELECTRICAL SPECIFICATION
EVC02-AC22 Series
Class I
Socket Outlet TYPE 2 (IEC 62196)
22kW
DC 6mA
4P-40A MCB Type-C
40A - 30mA RCCB Type-A
5x 6 mm² (< 50 m)
External Dimensions: Ø 15-21 mm
ISO-14443A/B and ISO-15693
MECHANICAL SPECIFICATION
Aluminum
180.0 mm (Width) x 646.7 mm (Height) x 183.5 mm (Depth)
180.0 mm (Width) x 646.7 mm (Height) x 197.3 mm (Depth)
245.0 mm (Width) x 710.0 mm (Height) x 270.0 mm (Depth)
10.7 kg , 12 kg with packing
Ø 15-21 mm for 22kW and 11kW versions
ENVIRONMENTAL SPECIFICATION
Ingress Protection
Impact Protectıon
Temperature
Humidity
Altitude
AUTHORIZATION
IP54
IK10
-30 °C to + 50 °C
5 % - 95 % (Relative humidity, without dewdrops)
0 - 3.000m
English - 5 -
EVC02-AC11 Series
Class I
Socket Outlet TYPE 2 (IEC 62196)
400VAC 50/60 Hz - 3-phase 16A
11kW
DC 6mA
4P-20A MCB Type-C
20A - 30mA RCCB Type-A
5x 4 mm² (< 50 m)
External Dimensions: Ø 15-21 mm