10.4 Capacitance measurement
WARNING: Never test on a live circuit. Remove all power from the cir-
cuit and discharge all capacitors before testing.
1. Set the rotary switch to:
2. Press the SELECT button until the display shows "n" and "F".
3. Connect the test leads to the input terminals:
- Black test lead to the negative input terminal: COM.
- Red test lead to the positive input terminal:
4. Touch the test probe tips across the capacitor under test. It may take a few mo-
ments for the reading to stabilize.
à
The measurement will show on the display.
à
The display will show icon
ceeded or the circuit is interrupted.
5. Disconnect the test leads and switch the power OFF after use.
56
.
(overload) if the measuring range is ex-
.

Werbung