CLEO COMBI
Problem
The walls inside
the stove
become
excessively dirty
during
functioning
The fire burns
well but the stove
and the room do
not heat up
The pellet burns
too quickly
Smoke escaping
in the room
during normal
functioning
The flue
becomes wet and
covered with
soot with
condensate
escaping from
the pipes
The flame only
burns slightly
even if the
primary air valve
is open
8192000 Rev.04 – EN
Possible cause
Butterfly valve in the closed flue
Flue gas exhaust pipe blocked by
soot
Flue draught too low
Insufficient inlet primary air
Burner dirty and blocked
Worn gaskets
Upper
inspection
lid
incorrectly
Excessive flue draught
Room of installation too big or with
dispersion points of excessive heat.
Excessive flue draught
Excessive inlet air
Butterfly valve in the closed flue
Flue gas exhaust pipe blocked by
soot
Flue draught too low
Burner dirty and blocked
Worn gaskets
Upper
inspection
lid
incorrectly
The flue is too cold
The transversal section of the flue is
excessive
Butterfly valve in the closed flue
Flue draught too low
Burner dirty and blocked
Worn gaskets
Upper
inspection
lid
incorrectly
Butterfly valve in the closed flue
Flue gas exhaust pipe blocked by
soot
Flue draught too low
Insufficient inlet primary air
Burner dirty and blocked
Worn gaskets
Upper
inspection
lid
incorrectly
The pellets do not slide into the tank
Check that the flue is not obstructed by soot, which the
butterfly for draught regulation is not completely closed
and that draught between 14 and 17 Pa is guaranteed.
Increase the inlet air using the regulation knob ( R ) and
clean the flue gas exhaust pipe.
Use the grate shaker combs to clean the burner
Check the correct position of the upper inspection lid
Check sealing of the upper lid gaskets, of the intermediate
base of the tank, the lateral inspection lid and the upper
positioned
inspection lid. If they are worn, contact qualified staff for
their replacement
Regulate draught to between 14 and 17 Pa using the
butterfly in the flue
Insulate the room as well as possible in order to limit heat
dispersion
Regulate draught to between 14 and 17 Pa using the
butterfly in the flue
Reduce the inlet primary air using the regulation knob ( R
)
Check that the flue is not obstructed by soot, which the
butterfly for draught regulation is not completely closed
and that draught between 14 and 17 Pa is guaranteed.
Increase the inlet air using the regulation knob ( R ) and
clean the flue gas exhaust pipe.
Use the grate shaker combs to clean the burner
Check the correct position of the upper inspection lid
Check sealing of the upper lid gaskets, of the intermediate
positioned
base of the tank, the lateral inspection lid and the upper
inspection lid. If they are worn, contact qualified staff for
their replacement
Al piping must be isolated
Reduce flue section
Check that the flue is not obstructed by soot, which the
butterfly for draught regulation is not completely closed
and that draught between 14 and 17 Pa is guaranteed.
Use the grate shaker combs to clean the burner
Check the correct position of the upper inspection lid
Check sealing of the upper lid gaskets, of the intermediate
positioned
base of the tank, the lateral inspection lid and the upper
inspection lid. If they are worn, contact qualified staff for
their replacement
Check that the flue is not obstructed by soot, which the
butterfly for draught regulation is not completely closed
and that draught between 14 and 17 Pa is guaranteed.
Increase the inlet air using the regulation knob ( R ) and
clean the flue gas exhaust pipe.
Use the grate shaker combs to clean the burner
Check the correct position of the upper inspection lid
Check sealing of the upper lid gaskets, of the intermediate
base of the tank, the lateral inspection lid and the upper
positioned
inspection lid. If they are worn, contact qualified staff for
their replacement
Check the opening of the lever that blocks sliding of the
pellet into the tank and clean the tank if necessary.