Herunterladen Inhalt Inhalt Diese Seite drucken

Normal Functioning - Nordica CLEO COMBI Holz Bedienungsanleitung

Inhaltsverzeichnis

Werbung

Verfügbare Sprachen

Verfügbare Sprachen

CLEO COMBI
2) Release the lever (C) (Picture 9) raising the lockbolt (D), pushing it towards the front of the stove in the position
marked with the letter P (PELLET) and block it with the lockbolt (D), vertical grate (G) in cast iron;
3) check that the hatch of the pellet feeding tank (S) is closed and locked using the handle (B) (Picture 9);
4) close the lateral access door(L) to the mechanical parts.
ATTENTION: before lighting, the stove must be as in the original
state, i.e. with the side door and the tank lid closed using the
handle.
The lighting procedure is manual and envisions the following points:
IMPORTANT: for correct and uniform lighting, it is necessary to use a
pair of fire-lighter cubes (Picture 10 pos.1 pos.2).
Check that the register of the primary air is completely open;
Open the upper door;
Place the relevant supplied chute (Picture 10 pos.A) on the grate
and in the rear edge of the burner caps (pos.1 pos.2);
Place a fire-lighter cube on the chute, light it and make it slide
inside the burner;
When the two cubes have been lit in pos.1 and pos.2, remove the
chute and close the fire door.
ATTENTION: do not use any inflammable liquids for lighting.
When lighting has taken place, the user can adjust the heating power
through the primary air register (R) from the minimum power (register
towards left) to the maximum power (register towards right completely
open).
ATTENTION:
• The lid of the pellet container must always be closed. It must only
be opened during the fuel feeding phase.
• The bags of pellets must be kept at least 1.5 metres from the
stove.
• Do not allow the bag of pellets to come into contact with the
boiling hot stove during the filling phase

10. NORMAL FUNCTIONING

During normal stove functioning of the pellet stove, the cinders must be
shaken to prevent stratification of the ash. (see par. 14.3 – 14.4)
The appliances with automatic door closure (type 1) must function, for
safety reasons, with the hearth door closed (except for the fuel feeding
phase or removal of ash).
The appliances with constructive system type 2 must be connected to
their own flue. The operating with open door is allowed under supervision.
IMPORTANT: For safety reasons, the hearth door can only be
opened when feeding the fuel. The hearth must remain closed
during functioning and standstill periods.
The nominal calorific value of the stove is equal to 6.4kw-wood / 6kw-
pellet and is reached with minimum draught (depression) of 12 Pa (= 1.2
mm of water column).
Using the registers ( R ) on the stove face (Picture 1) regulate the emission of heat from the hearth.
These must be opened according to the heat requirement.
Never overfeed the stove (consult the technical table – max. quantity of fuel that can be fed).
Too much fuel and too much air for combustion can cause overheating and therefore damage the stove . The
damage caused by overheating is not covered by the warranty.
The stove must therefore always be used with the door closed to prevent the forge effect (Picture 1 pos.B).
This product is an appliance with timed combustion.
As well as the regulation of the air for combustion, the intensity of combustion and therefore the calorific yield of your
stove is affected by the chimney. Good draught of the chimney requires a reduced regulation of the air for
combustion, while slight draught requires the exact regulation of the air for combustion.
8192000 Rev.04 – EN
B
2
1
1
2
CB
G
A
A
P
C
D
Picture 9
Picture 10
29