Herunterladen Diese Seite drucken

Balluff BTL7-A/C/E/G5 M Serie Betriebsanleitung Seite 47

Vorschau ausblenden Andere Handbücher für BTL7-A/C/E/G5 M Serie:

Werbung

Verfügbare Sprachen
  • DE

Verfügbare Sprachen

  • DEUTSCH, seite 1
BTL7-A/C/E/G5 _ _ -M _ _ _ _ -K(8)-SR32/SR115/_ _ _
Micropulse Transducer - Rod Style
10
Technical data
10.1
Accuracy
The specifications are typical values for the
BTL7-A/C/E/G... at 24 V DC and room temperature, with a
nominal length of 500 mm in conjunction with the
BTL-P-1013-4R, BTL-P-1013-4S, BTL-P-1012-4R or
BTL-P-1014-2R magnet.
The BTL is fully operational immediately, with full accuracy
after warm-up.
For special versions, other technical data may
apply.
Special versions are indicated by the suffix -SA
on the part label.
Repeat accuracy
Typical
Sampling rate
Dependent on the nominal length
At nominal length = 500 mm
Non-linearity at
Nominal length ≤ 500 mm
Nominal length > 500 to ≤ 5500 mm
Nominal length > 5500 mm
Temperature coefficient
(nominal length = 500 mm, magnet
in the middle of the measuring range)
Max. detectable velocity
10.2
Ambient conditions
Operating temperature
Storage temperature
Relative humidity
Rod pressure rating (when
installed in hydraulic cylinders)
For Ø 8 mm
For Ø 10.2 mm
Shock rating
per EN 60068-2-27
1)
Continuous shock
per EN 60068-2-29
1)
Vibration
per EN 60068-2-6
1)
(note resonant frequency
of the rod)
Degree of protection per
IEC 60529
Connector SR32/SR115
(when attached)
Cable
20
english
±10 µm
250 µs to 5.5 ms
500 µs
±50 µm
±0.01% FS
±0.02% FS
≤ 30 ppm/K
10 m/s
-40°C to +85°C
-40°C to +100°C
< 90%, non-
condensing
< 250 bar
< 600 bar
150 g/6 ms
150 g/2 ms
20 g, 10 to 2000 Hz
IP67
IP68
1)
10.3
Supply voltage (external)
Voltage, stabilized
:
2)
BTL7-_5_ _-...
Ripple
Current draw
(at 24 V DC)
Inrush current
Reverse polarity
protection
3)
Overvoltage protection
Dielectric strength
(GND to housing)
10.4
Output
BTL7-A... Output voltage
Load current
BTL7-C... Output current
Load resistance
BTL7-E... Output current
Load resistance
BTL7-G... Output voltage
Load current
Short-circuit resistance
10.5
Input
Programming inputs La, Lb:
BTL7-_5_ _-...
Overvoltage protection
1)
Individual specifications as per Balluff factory standard
2)
For
: The transducer must be externally connected via a limited-
energy circuit as defined in UL 61010-1, a low-power source as defined in
UL 60950-1, or a class 2 power supply as defined in UL 1310 or
UL 1585.
3)
A prerequisite is that no current can flow between GND and 0 V in the
event of polarity reversal.
10 to 30 V DC
≤ 0.5 V
ss
< 120 mA
≤ 500 mA/10 ms
Up to 36 V
Up to 36 V
500 V AC
0 to 10 V and 10 to 0 V
≤ 5 mA
0 to 20 mA/20 to 0 mA
≤ 500 ohms
4 to 20 mA/20 to 4 mA
≤ 500 ohms
-10 to 10 V and 10 to -10 V
≤ 5 mA
Signal cable to 36 V
Signal cable to GND
High-active
10 to 30 V DC
Up to 36 V

Werbung

loading