Insert the quick-lock fasteners of the Omega-clamp into the respective holes on the bottom of the device.
Tighten the quick-lock fasteners fully clockwise.

DMX-512 connection / connection between fixtures

Projector 3
Starting address 31
120 Ohms
The wires must not come into contact with each other, otherwise
Please note, the starting address depends upon which controller is being used.
Only use a DMX-cable and 3-pin XLR-plugs and connectors in order to connect the controller with the fixture
or one fixture with another.
Occupation of the XLR-connection:
If you are using controllers with this occupation, you can connect the DMX-output of the controller directly
with the DMX-input of the first fixture in the DMX-chain. If you wish to connect DMX-controllers with other
XLR-outputs, you need to use adapter-cables.
Building a serial DMX-chain:
Connect the DMX-output of the first fixture in the DMX-chain with the DMX-input of the next fixture. Always
connect one output with the input of the next fixture until all fixtures are connected.
Caution: At the last fixture, the DMX-cable has to be terminated. Plug the terminator with a 120
between Signal (–) and Signal (+) in the DMX-output of the last fixture.
Projector 2
Starting address 16
the fixtures will not work at all, or will not work properly.
Projector 1
Starting address 1
24/32
DMX-512 Controller
resistor
00101665, Version 1.0

Quicklinks ausblenden: