operation | installation
safety
7
Safety
7.1
country-specific safety information
All required steps up to and including commissioning must be
carried out by a qualified contractor. During this process, these
installation instructions must be observed.
We guarantee troublefree function and operational reliability
only if original accessories and spare parts intended for the tap
are used.
7.2
Instructions, standards and regulations
Observe all applicable national and local instructions
!
and regulations, e.g. DIN 1988 and EN 806 in
Germany.
8
Standard delivery
The standard delivery is shown in the following diagram. The
WBMD tap is shown here as an example.
9
8
7
1
Water inlet pipe
2
Hand shower with fork (WBMD)
3
Spout with perlator
4
Wall connector for cold water connection
5
Post anchor base (alternative to the wall connector)
6
Cold water handle
7
Tap body
8
Changeover control spout hand shower
9
Hot water handle
www.stiebel-eltron.com
1
2
6
5
4
3
9
Installation conditions
The tap is intended for a static pressure of up to 0.6 MPa. Install
a pressure reducer upstream of the tap in the water mains if the
static pressure is higher.
10 Installation
10.1 cold water connection via tap
»
Secure the wall connectors supplied into the wall.
»
Insert the tap bodies into the wall connectors.
»
Seal off the below surface connections of the instantaneous
water heater using the plugs provided with the tap.
10.2 cold water connection via instantaneous
water heater
»
Secure the post anchor base provided to the wall.
»
Insert the tap bodies into the post anchor base.
10.3 connecting the instantaneous water heater
»
Debur the pipes if you have reduced them.
»
Insert the water inlet pipes to connect the instantaneous water
heater and the tap body.
»
Insert the pivoting spout with the shower hose and fork for the
hand shower into the tap body.
11 Commissioning
»
Disconnect the mains fuse of the instantaneous water heater.
»
Open the left tap handle.
»
Wait until the water is flowing from the spout without bubbles.
»
Reconnect the mains fuse of the instantaneous water heater.
Wkmd | WBmd|