Quick
Start Guide
Fronius Tauro
50-3-D / 50-3-P
Eco 50-3-D / Eco 50-3-P
Eco 99-3-D / Eco 99-3-P
Eco 100-3-D / Eco 100-3-P
manuals.fronius.com/
html/4204260307
OPERATING
INSTRUCTIONS
42,0410,2570
017-01022024

Werbung

loading

Inhaltszusammenfassung für Fronius Tauro 50-3-D

  • Seite 1 Quick Start Guide Fronius Tauro 50-3-D / 50-3-P Eco 50-3-D / Eco 50-3-P Eco 99-3-D / Eco 99-3-P Eco 100-3-D / Eco 100-3-P manuals.fronius.com/ html/4204260307 OPERATING INSTRUCTIONS 42,0410,2570 017-01022024...
  • Seite 2 (both hard copies enclosed with the product and documents provided online). When solar modules are exposed to light, they supply voltage to the inverter. This document does not describe all of the possible system configurations. Fronius International GmbH declares that the radio equipment type Fronius Tauro is in compliance with Directive 2014/53/EU.
  • Seite 3 PV-installaties die aan licht worden blootgesteld, leveren spanning aan de omvormer. Dit document beschrijft niet alle mogelijke systeemconfi- guraties. Fronius International GmbH verklaart hierbij dat het radiosysteem Fronius Tauro voldoet aan Richtlijn 2014/53/EU. De volledige tekst van de EU-conformiteitsverklaring is beschikbaar op het volgende internetadres: www.fronius.com TR: UYARI! Hatalı...
  • Seite 4 Mounting Variant Floor 3rd-party components area V-CLAMP size change V-CLAMP to cable gland Optional PE input The opening must be sealed! Secure to the torque speci- fied by the manufacturer User manual...
  • Seite 5 Tauro 50-3 / Eco 50-3: 35 - 240 mm² * Tauro Eco 99-3 / 100-3: 70 - 240 mm² * * N can be reduced to 25 mm² - see local regulations Cable (min 90° C) cross section ≥ ≥ AC~ Variant Singlecore AC~ Variant Multicore Secure to the torque spe-...
  • Seite 6 AC~ Variant Daisy Chain Secure to the torque spe- cified by the manufacturer AC~ Variant PEN...
  • Seite 7 Max. PV array to earth capacitance (nF) Tauro 50-3-D / Tauro 50-3-P / 10000 nF Tauro Eco 50-3-D / 50-3-P Tauro Eco 99-3-D / 19998 nF Tauro Eco 99-3-P Tauro Eco 100-3-D / 20000 nF Tauro Eco 100-3-P DC= Variant Precombined...
  • Seite 8 DC= MC4 alignment DC= fuse change DC= Variant MC4 fuses Eco 50-3-D / Eco 50-3-D 208-220 Eco 99-3-D / Eco 100-3-D 50-3-D Eco 99-3-D / Eco 100-3-D Standard Standard F1.1 - F3.7 F1.1 - F2.7 F3.1 - F3.8 Close Insert data cables if necessary Commissioning 2-3x Switch...
  • Seite 9 Standby Connected Uncritical Error Connecting (flashing) (flashing) Network Error Critical Error Setup with mobile phone Fronius Solar.start open access point Setup with PC - Ethernet 192.168.250.180 open access point Setup with PC - WLAN Rating plate FRONIUS_Serialnumber Secured Access point 192.168.250.181...
  • Seite 10 *Not in use PE-LD...
  • Seite 12 MONITORING & DIGITAL TOOLS Fronius International GmbH Froniusstraße 1 4643 Pettenbach Austria contact@fronius.com www.fronius.com Under www.fronius.com/contact you will find the adresses of all Fronius Sales & Service Partners and locations.