Herunterladen Diese Seite drucken

Grohe GET E 36 366 Bedienungsanleitung Seite 12

Vorschau ausblenden Andere Handbücher für GET E 36 366:

Werbung

Verfügbare Sprachen
  • DE

Verfügbare Sprachen

  • DEUTSCH, seite 11
Safety notes
•Installation is only possible in frost-free rooms.
•Use only genuine replacement parts and
accessories. The use of other parts will result in
voiding of the warranty and the CE identification, and
could lead to injuries.
Technical data
• Flow pressure:
- min.
- recommended
• Operating pressure:
• Test pressure:
• Flow rate at 0.3 MPa flow pressure:
• Hot water supply temperature:
Recommended (energy economy):
Thermal disinfection possible
• Voltage supply:
• Automatic safety shut-off:
(6 - 420 s adjustable)
• Run-on time (0 - 11 s adjustable):
• Reception range according to Kodak Gray Card,
grey side, 8x10", landscape (7 - 20cm adjustable):
• Type of fitting protection:
Thermal disinfection possible.
Electrical test data
• Software class
• Contamination class
• Rated surge voltage
• Temperature of ball impact test
The test for electromagnetic compatibility (interference emission
test) was performed at the rated voltage and rated current.
If static pressures exceed 0.5 MPa, a pressure-reducing valve
must be installed.
Avoid major pressure differences between hot and cold water
supply!
Fault / Cause / Remedy
Fault
Cause
Water not flowing
• Filter upstream of solenoid valve blocked
• Solenoid valve defective
• Plug-in connector without contact
• No voltage
Undesired water
• Sensor system detection zone set too high
flow
• Automatic flushing activated
• Solenoid valve defective
Flow rate too low
• Mousseur dirty
• Filter upstream of solenoid valve dirty
• Filters in connection hose dirty
0.1 - 0.5 MPa
6V lithium battery type CR-P2
- Battery discharged
(indicator lamp lights up continuously)
for local conditions
GB
0.05 MPa
max. 1 MPa
1.6 MPa
5,7 l/min
max. 70 °C
60 °C
60 s
1 s
13cm
IP 59K
Care
A
For directions on the care of this fitting, please refer to the
2
accompanying Care Instructions.
2500 V
100 °C
Remedy
- Clean filter
- Replace solenoid valve
- Check plug-in connector
- Replace battery
- Reduce range using remote control (special
accessory, prod. no.: 36 407)
- Wait 1 - 10 minutes
- Replace solenoid valve
- Clean or replace mousseur
- Clean filter
- Clean or replace filters
11
Installation
, see page 2.
Flush pipes thoroughly before and after
installation (observe EN 806)!
Open hot and cold water supply and check that
connections are watertight.
Setting temperature limiter,
see page 2.
Operation,
see technical product information, 99.0438.xxx.
Maintenance
, see page 3 - 4.
•Shut off hot and cold water supply.
•Disconnect voltage supply.
•Inspect and clean all components and replace if
necessary.
Replacement parts
see page 12 (* = special accessories)
,
2

Werbung

loading