table below.
230-240V
3G 2,5 mm
2
max 20 m
PLEASE NOTE: This water cleaner is equipped
with the A.S.S. (Automatic Stop System), which
stops the machine during the bypass phase. To
start the water cleaner, it is therefore necessary
to set the switch on position "ON"; after that
press the pistol trigger: the Automatic Stop
System will start the machine and will stop it
automatically when the trigger is released. It is
advisable to put on the safety of the pistol trig-
ger whenever the machine is stopped, in order
to avoid unintentional starting.
• Any automatic start of the machine with-
out pressing the gun trigger is attributable
to air bubbles in the water or other similar
phenomena which do not imply the exist-
ence of any defects in the machine.
• Do not leave the appliance unattended
during the standby for more than 5 minutes.
Contrarily, for the safety of the appliance it
is necessary to re-turn the switch into the
OFF position.
• Please check that the coupling of the high
pressure hose with the appliance and the
gun supplied as standard equipments made
correctly, that is to say without any water
leak.
If the appliance is equipped with a pressure
regulator:
• when the pressure is set to minimum the
A.S.S. may not trigger. Therefore, do not al-
low the appliance to function in by-pass for
more than 1 minute.
• do not act on the gun lever too frequently
(this may cause a malfunction).
>
400-415V
The performances of the machine are suitable
for a professional use. Structural technologies
4G 2,5 mm
2
have been studied to assure high reliability and
max 30 m
safety levels, and long life. It is absolutely for-
bidden to use the machine in potentially explo-
sive environments or areas.
The working temperature must range between
+ 5° and + 50°C. It is forbidden to carry out any
(if fi tted)
modifi cation to the structure and to any ele-
ments of the machine.
CORRECT USE OF THE MACHINE
• The cleaner must be placed on a fi rm, stable
surface and must be horizontal.
• In case of operation indoors, adequate venti-
lation and gas venting must be assured.
• Whenever using the high-pressure cleaner,
users are urged to hold the gun in the correct
position, with one hand on the grip and the
other on the spray rod.
• The water jet must never be pointed at the
electrical cables or at the machine.
>
INSTALLATION
The equipment must be installed on a sturdy,
perfectly fl at surface. Fasten to the fl oor with 4
steel wedges Ø 1 (see ref. 2).
The fl oor must be suitable for this kind of fas-
tening.
ST
1
When starting up for the fi rst time or after a
long period out of use, connect the intake line
only for a few minutes so that any dirt is vented
from the delivery outlet.
ELECTRICAL CONNECTION
Check that the mains voltage is the same as
that of your machine, indicated on the techni-
cal data plate. Your electrical system must be
constructed by qualifi ed technicians capable of
working in accordance with the requirements
of the regulations in force (earth connection,
fuses, diff erential security breaker, etc).
The connection to the mains must be carried
SUITABLE USE OF THE MACHINE
INSTALLATION AND START-UP
START-UP
23